Seed laser priming enhances defensive responses in milk thistle under Pb toxicity.

Sci Rep

Plant Science Department, Faculty of Science, Shahrekord University, Shahrekord, Iran.

Published: March 2025

Heavy metal stress negatively affects the growth of medicinal plants. While the effects of Helium-Neon (He-Ne) laser on seed germination and stress tolerance in plants has garnered significant attention, little is known concerning the impacts of He-Ne laser irradiation on heavy metal tolerance in plants. Therefore, the current study was conducted to appraise the effect of different durations (0, 20, and 40 min) of seed priming with He-Ne laser (10 mW mm) on the antioxidant system of Silybum marianum L. plants under various Pb concentrations (0, 250, and 500 ppm). Lead phytotoxicity was evident by significant reductions in fresh and dry weights of shoots and roots, total chlorophyll (TChl) content and relative water content (RWC), as well as increases in HO and malondialdehyde contents in roots and leaves. Seed irradiation with He-Ne laser for 20 min significantly improved these parameters, enhancing Pb tolerance. Conversely, the prolonged laser priming (40 min) resulted in less favorable outcomes, including reduced growth, TChl content, and RWC, while also exacerbating oxidative damage to membranes even under non-stressful conditions. The 20-min laser priming systemically mitigated Pb-induced lipid peroxidation and HO accumulation by boosting the activities of superoxide dismutase and catalase and increasing proline content in leaves and roots of milk thistle plants. These findings and multivariate analysis suggest that optimal dose of laser initiates a "stress memory" in seeds which is activated upon subsequent exposure to Pb stress, boosting the plant defensive mechanisms and enabling the plant to better cope with oxidative damage. This study underscore the promising potential of He-Ne laser priming as a novel strategy for increasing heavy metal tolerance in medicinal plants like milk thistle, offering an eco-friendly technique for maintaining their productivity under heavy metal stress.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11885596PMC
http://dx.doi.org/10.1038/s41598-025-92414-wDOI Listing

Publication Analysis

Top Keywords

he-ne laser
20
laser priming
16
heavy metal
16
milk thistle
12
metal stress
8
medicinal plants
8
laser
8
tolerance plants
8
metal tolerance
8
tchl content
8

Similar Publications

Heavy metal stress negatively affects the growth of medicinal plants. While the effects of Helium-Neon (He-Ne) laser on seed germination and stress tolerance in plants has garnered significant attention, little is known concerning the impacts of He-Ne laser irradiation on heavy metal tolerance in plants. Therefore, the current study was conducted to appraise the effect of different durations (0, 20, and 40 min) of seed priming with He-Ne laser (10 mW mm) on the antioxidant system of Silybum marianum L.

View Article and Find Full Text PDF

Compact and full-range carbon dioxide sensor using photoacoustic and resonance dependent modes.

Photoacoustics

February 2025

Dipartimento di Scienze di Base ed Applicate per l'Ingegneria, Sapienza Università di Roma, Rome 00161, Italy.

A compact and robust optical excitation photoacoustic sensor with a self-integrated laser module excitation and an optimized differential resonator was developed to achieve high sensitivity and full linear range detection of carbon dioxide (CO) based on dual modes of wavelength modulated photoacoustic spectroscopy (WMPAS) and resonant frequency tracking (RFT). The integrated laser module equipped with three lasers (a quantum cascade laser (QCL), a distributed feedback laser (DFB) and a He-Ne laser) working in a time-division multiplexing mode was used as an integrated set of spectroscopic sources for detection of the designated concentration levels of CO. With the absorption photoacoustic mode, the WMPAS detection with the QCL and DFB sources was capable of CO detection at concentrations below 20 %, yielding a noise equivalent concentration (NEC) as low as 240 ppt and a normalized noise equivalent absorption coefficient (NNEA) of 4.

View Article and Find Full Text PDF
Article Synopsis
  • * Different exposure times (0 to 3 minutes) showed that most mechanical parameters improved with laser stimulation, indicating stronger seeds, except for a decrease in the force-to-deformation ratio after longer stints.
  • * Findings suggest that using laser stimulation could enhance seed strength, potentially leading to the development of more resilient crops.
View Article and Find Full Text PDF

In this paper, we propose a high-precision dual-comb ranging (DCR) method for short-distance measurement, avoiding carrier-envelope-offset locking. Cross-polarization detection is introduced, which makes better use of the intrinsic coherence of interferogram pairs over a short distance. We analyze the noise in the DCR system and propose a carrier-wave phase difference (CPD) calculation algorithm based on centroid extraction.

View Article and Find Full Text PDF
Article Synopsis
  • Plantar warts, benign growths on the feet caused by HPV, are tough to eliminate completely, often leading to reappearance; this study looks at a dual treatment approach.
  • Data from 10 patients with stubborn warts were analyzed after undergoing a combination of CO laser treatment and 5-ALA photodynamic therapy, yielding a 70% overall lesion clearance rate.
  • This combined therapy proved to be effective and safe, suggesting it could be a good alternative for treating difficult plantar wart cases with minimal side effects.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!