A multi-point calibration method for electron probe microanalysis (EPMA) of indium in sphalerite (ZnS).

Sci Rep

Institute of Disposal Research, Clausthal University of Technology, Adolph-Römer-Str. 2A, D- 38678, Clausthal-Zellerfeld, Germany.

Published: March 2025

This article presents a multi-point calibration approach for electron probe microanalysis (EPMA) for the trace element analysis of indium in sphalerite (ZnS). To define a multi-point calibration curve, indium and cadmium-doped ZnS crystals in a concentration range from 0 (blank) to ~ 1500 µg / g were used. The samples were measured with two different analytical settings (25 kV acceleration voltage and 100 nA beam current as well as 7 kV and 200 nA). The figures of merit including, beam stability, lower limit of detection and limit of quantification as well as the reproducibility and precision are assessed. Equally, the line overlap of Cd and chemical shift due to non-matrix matched standards is discussed. The multi-point calibration approach results in a 2-3 times improved analytical precision compared to the classical calibration approach using only one calibration sample, and detection limits down to about 20 µg / g were achieved.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11885527PMC
http://dx.doi.org/10.1038/s41598-025-91085-xDOI Listing

Publication Analysis

Top Keywords

multi-point calibration
16
calibration approach
12
electron probe
8
probe microanalysis
8
microanalysis epma
8
indium sphalerite
8
sphalerite zns
8
calibration
5
multi-point
4
calibration method
4

Similar Publications

A multi-point calibration method for electron probe microanalysis (EPMA) of indium in sphalerite (ZnS).

Sci Rep

March 2025

Institute of Disposal Research, Clausthal University of Technology, Adolph-Römer-Str. 2A, D- 38678, Clausthal-Zellerfeld, Germany.

This article presents a multi-point calibration approach for electron probe microanalysis (EPMA) for the trace element analysis of indium in sphalerite (ZnS). To define a multi-point calibration curve, indium and cadmium-doped ZnS crystals in a concentration range from 0 (blank) to ~ 1500 µg / g were used. The samples were measured with two different analytical settings (25 kV acceleration voltage and 100 nA beam current as well as 7 kV and 200 nA).

View Article and Find Full Text PDF

The proposed photoluminescence calibration standard comprises a solid-state phosphor film, neutral density gel filter(s), and a 3D-printed optomechanical cartridge. The proposed standard demonstrated exceptional photostability; photoluminescence did not deviate from the baseline more than 1.27% under 5 minutes of continuous illumination.

View Article and Find Full Text PDF

We present a spectroscopic method that employs a single linearly chirped laser pulse (LCLP) generated by external modulation to realize long-distance multi-point gas sensing. Even without frequency-chirping calibration, accurate single-shot spectral measurement is rendered possible by the high linearity of intrapulse chirping (linearity error of ∼10). Utilizing the LCLP's built-in capacity of time-division-multiplexing, high measurement sensitivity is guaranteed by introducing a multichannel intensity noise compensation mechanism.

View Article and Find Full Text PDF

Targeted metabolomics is often criticized for the limited metabolite coverage that it offers. Indeed, most targeted assays developed or used by researchers measure fewer than 200 metabolites. In an effort to both expand the coverage and improve the accuracy of metabolite quantification in targeted metabolomics, we decided to develop a comprehensive liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay that could quantitatively measure more than 700 metabolites in serum or plasma.

View Article and Find Full Text PDF

C-type two-thermocouple sensor design between 1000 and 1700 °C.

Rev Sci Instrum

October 2024

Key Laboratory of Instrumentation Science and Dynamic Measurement, Ministry of Education, North University of China, Taiyuan, Shanxi 030051, China.

Article Synopsis
  • Current methods of measuring temperature changes in boron-containing warm-pressure explosives using single thermocouples are ineffective due to their inconsistent performance.
  • A new C-type two-thermocouple has been developed to enhance transient temperature measurement with improved system characterization and optimal solution finding methods.
  • Experimental validation in a high-temperature furnace demonstrated that the two-thermocouple setup yields better temperature measurement accuracy, achieving a low error rate and high goodness of fit.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!