Location estimation of UWB-based wireless capsule endoscopy using TDoA in various gastrointestinal simulation models.

PLoS One

Centre for Wireless Communications-Networks and Systems, Faculty of Information Technology and Electrical Engineering, University of Oulu, Oulu, Finland.

Published: March 2025

Wireless capsule endoscopy (WCE) is a revolutionary field that aids in treating gastrointestinal disorders. For the development of a futuristic endoscopic capsule, identifying the location of abnormality is challenging yet a crucial step in determining the treatment procedure. Though the present-day wireless capsule endoscopes certified for endoscopic procedures predominantly work on the Medical Implant Communication System (MICS) band, the applications based on the Ultra-Wide Band (UWB) are gaining popularity for their immense possibilities. While received signal strength, time of arrival, phase of arrival, and angle of arrival are the basic parameters applied in research for location estimation of WCE, this paper uses a time difference of arrival (TDoA) approach using the Chan algorithm. To test the effectiveness of the algorithm, a series of UWB propagation experiments are performed utilizing human voxel models to find out the variance in distance error using an advanced electromagnetic simulation environment, which is then applied as the error to the distance estimate of the Chan algorithm, and the performance is analysed using different cases. Positioning receivers in three rows reduces the estimation error by 44%, and positioning the reference receiver in the middle row reduces it by 33%. The algorithm performance is observed for different variances in the distance estimation using different numbers of receivers, and the results are compared to the Cramér-Rao lower bound (CRLB). The calculated error in thickness from the different sections of abdominal tissues of the individual voxel models is applied to the distance estimates from the corresponding receiver sections prior to the WCE location estimation. The RMSE in WCE location estimation is found for individual voxel models, and the error is observed to reduce approximately from 4 mm to 1 mm, with variations in individual models, when the number of receivers are increased from 9 to 33.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11884827PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0319167PLOS

Publication Analysis

Top Keywords

location estimation
16
wireless capsule
12
voxel models
12
capsule endoscopy
8
chan algorithm
8
algorithm performance
8
individual voxel
8
wce location
8
location
5
models
5

Similar Publications

Objective: Quantitative time of flight in transmission mode ultrasound computed tomography (TFTM USCT) is a promising, cost-effective, and non-invasive modality, particularly suited for functional imaging. However, TFTM USCT encounters resolution challenges due to path information concentration in specific medium regions and uncertainty in transducer positioning. This study proposes a method to enhance resolution and robustness, focusing on low-frequency TFTM USCT for pulmonary imaging.

View Article and Find Full Text PDF

Hexagonal (β-) NaYF and LiYF doped with trivalent lanthanide ions (Ln, , Er, Tm, and Yb) are well-known photon upconverting materials. This property is crucially determined by the precise location of the Ln dopant ions and their closest neighbouring ions in the host material. However, due to the inherent disorder of the crystal structures the atomistic structure of a disordered crystal such as β-NaYF is not unambiguously provided by X-ray diffraction techniques.

View Article and Find Full Text PDF

Prevalence and Factors Associated With Hepatitis C Virus in Riyadh, Saudi Arabia: A Large Cross-Sectional Study.

J Epidemiol Glob Health

March 2025

Department of Public Health, College of Public Health and Health Informatics, King Saud Bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia.

Introduction: Viral hepatitis stands accountable for approximately 1.34 million deaths worldwide, with the number of fatalities steadily growing with time. This is partly due to the various genotypes of hepatitis C virus and having no vaccination developed yet.

View Article and Find Full Text PDF

The segmented model has significant applications in scientific research when the change-point effect exists. In this article, we propose a comprehensive semiparametric framework in segmented models to test the existence and estimate the location of change points in the generalized outcome setting. The proposed framework is based on a semismooth estimating equation for the change-point estimation and an average score-type test for hypothesis testing.

View Article and Find Full Text PDF

Background: The accurate determination of the working length (WL) is imperative for endodontic success.

Objectives: Our objective was to systematically analyze the available evidence on the impact of voxel size variation on the estimation of WL using cone-beam computed tomography (CBCT).

Material And Methods: An electronic search of the PubMed, Scopus, Embase, and Web of Science databases was conducted according to specific inclusion and exclusion criteria in March 2022.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!