Model-Based Inference of Electrode Distance and Neuronal Density from Measured Detection Thresholds in Cochlear Implant Listeners.

J Assoc Res Otolaryngol

Department of Otolaryngology, Head and Neck Surgery and Eaton Peabody Laboratories, Massachusetts Eye and Ear, Harvard Medical School, 243 Charles Street, Boston, MA, 02114, USA.

Published: March 2025

Purpose: Cochlear implants (CI) are a highly successful neural prosthesis that can restore hearing in individuals with sensorineural hearing loss. However, the extent of hearing restoration varies widely. Two major factors likely contribute to poor performance: (1) the distances between electrodes and surviving spiral ganglion neurons and (2) the density of those neurons. Reprogramming the CI at a poor electrode-neuron interface, using focused tripolar stimulation or remapping the electrodes, would benefit from understanding the cause of the poor interface.

Methods: We used a cochlear model with simplified geometry and neuronal composition to investigate how the interface affects stimulation thresholds. We then inverted the model to infer electrode distance and neuronal density from monopolar and tripolar threshold values obtained behaviorally. We validated this inverted model for known scenarios of electrode distance and neuronal density. Finally, we assessed the model using data from 18 CI users whose electrode distances were measured from CT imaging.

Results: The inverted model accurately inferred electrode distance and neuronal density for known scenarios. It also reliably reproduced behavioral monopolar and tripolar threshold profiles for CI users, with mean prediction errors within 1 dB for 17/18 subjects. Fits of electrode distance were more variable; accuracy depended on the assumed value of temporal bone resistivity. Twelve subjects had minimum distance error (0.31 mm) using low resistivity (70 Ω-cm) while the others had better fits (0.30 mm) with higher resistivity (250 Ω-cm).

Conclusion: This inverted model shows promise as a simple, practical tool to better assess and understand the electrode-neuron interface.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10162-025-00978-1DOI Listing

Publication Analysis

Top Keywords

electrode distance
20
distance neuronal
16
neuronal density
16
inverted model
16
electrode-neuron interface
8
monopolar tripolar
8
tripolar threshold
8
electrode
6
distance
6
model
6

Similar Publications

The gas sensitivity of field-effect structures with 2D-MoS channels selectively grown between Mo electrodes using the Mo-CVD method was investigated by measuring the effect of molecular adsorption from air on the device source-drain current ( ). The channels were composed of interconnected atomically thin MoS grains, with their density and average thickness varied by choosing two different distances (15 and 20 μm) between the Mo contacts. A high response to the tested stimuli, including molecule adsorption, illumination and gate voltage changes, was observed.

View Article and Find Full Text PDF

Introduction: Intracortical Brain-computer interfaces (iBCIs) are a promising technology to restore function after stroke. It remains unclear whether iBCIs will be able to use the signals available in the neocortex overlying stroke affecting the underlying white matter and basal ganglia.

Methods: Here, we decoded both local field potentials (LFPs) and spikes recorded from intracortical electrode arrays in a person with chronic cerebral subcortical stroke performing various tasks with his paretic hand, with and without a powered orthosis.

View Article and Find Full Text PDF

Formamide-assisted synthesis of phosphate-intercalated Ni(OH)/NiOOH electrode for boosting oxygen evolution reaction.

J Colloid Interface Sci

March 2025

Key Laboratory of Jiangxi Province for Environment and Energy Catalysis, School of Chemistry and Chemical Engineering, Nanchang University, Nanchang 330031, PR China.

Electrochemical water splitting (EWS) represents a promising method for green hydrogen production. However, the commercial viability of this approach is significantly hindered by the sluggish kinetics of the oxygen evolution reaction (OER). Layered Ni(OH)/NiOOH serves as a low-cost and effective OER electrocatalyst, yet the activity and stability do not meet the requirements for commercial EWS, particularly in terms of operational stability under high current densities.

View Article and Find Full Text PDF

DNA hairpin dimer-mediated dual-catalysis circuit for efficient and amplifiable electrochemical biosensing.

Biosens Bioelectron

March 2025

Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, Chongqing Engineering Laboratory of Nanomaterials & Sensor Technologies, School of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, PR China. Electronic address:

Exploring a variable catalytic hairpin assembly to amplify specific input might be intriguing for electrochemically detecting short-stranded DNA segment related to U. virens (iDNA). Herein, we proposed the first concept of hairpin dimer-mediated Dual-Catalysis Circuit (hdDCC) for creating rapid and efficient electrochemical biosensor.

View Article and Find Full Text PDF

Hierarchical Assembly of Conductive Fibers from Coiled-Coil Peptide Building Blocks.

ACS Nano

March 2025

Department of Chemical and Biomolecular Engineering, University of California, Irvine, Irvine, California 92697, United States.

Biology provides many sources of inspiration for synthetic and multifunctional nanomaterials. Naturally evolved proteins exhibit specialized, sequence-defined functions and self-assembly behavior. Recapitulating their molecularly defined self-assembly behavior, however, is challenging in proteins.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!