Unlabelled: Refractive anomalies are among the leading ocular conditions affecting the working-age population. One of them - high myopia - can cause severe and irreversible ocular changes, resulting in significant visual impairment or loss.
Purpose: This study evaluated changes in vault height of phakic intraocular lenses (PIOL) and intraocular pressure (IOP) following the implantation of the ICL V5 (VICM5) lens in patients with high myopia.
Material And Method: The study included 60 patients. They were monitored for at least 24 months. Observation included measurement of clinical refraction, uncorrected visual acuity (UCVA), IOP, and the distance between the posterior surface of the optical part of the lens and the anterior surface of the crystalline lens (vault).
Results: All surgeries were completed without complications. The safety and efficacy indices were 1.43 and 1.34, respectively. In 97 eyes (86%) with high myopia UCVA was equal to or better than preoperative values. The mean preoperative spherical equivalent was -10.59±3.4 D, which improved postoperatively to -0.5±0.75 D. Subsequently, the spherical equivalent remained within ±0.5 D in 89% of patients. The mean postoperative IOP was 15.86±3.30 mm Hg over the course of the 24-month follow-up. One month post-implantation, the vault height of the spherical lens ICL was 469.3±134.4 µm and 432.6±124.5 µm after 24 months (<0.001).
Conclusion: Implantation of the Visian ICL V5 lens is a safe and effective alternative refractive surgery method for the correction of high myopia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.17116/oftalma202514101128 | DOI Listing |
Purpose: To investigate the association of local ciliary body morphology with the haptic position and peripheral vault.
Methods: This retrospective observational study included 95 eyes of 59 patients treated with the EVO Implantable Collamer Lens (ICL) (STAAR Surgical). Ciliary body morphology parameters (ciliary process length [CPL], ciliary sulcus width [CSW], and scleral spur-ciliary process distance [SCD]), the relative position of ICL haptic to the ciliary process, the haptic-related parameters (the final tip point of ICL haptic [ftICL haptic] and lowest point of ICL haptic), and peripheral vault in the location of each haptic were measured with ultrasound biomicroscopy 3 months after surgery.
Vestn Oftalmol
March 2025
OOO Nazar Medical, Tashkent, Uzbekistan.
Unlabelled: Refractive anomalies are among the leading ocular conditions affecting the working-age population. One of them - high myopia - can cause severe and irreversible ocular changes, resulting in significant visual impairment or loss.
Purpose: This study evaluated changes in vault height of phakic intraocular lenses (PIOL) and intraocular pressure (IOP) following the implantation of the ICL V5 (VICM5) lens in patients with high myopia.
Vestn Oftalmol
March 2025
Purpose: This study investigated the correlation between iridotrabecular contact (ITC) and clinical-anatomical parameters in patients with primary angle closure disease (PACD) based on anterior segment imaging data obtained via swept-source optical coherence tomography (SS-OCT).
Material And Methods: The study analyzed data from 92 patients aged 32-89 years, including 56 patients with PACD (43 phakic and 13 pseudophakic) and 36 control group participants (21 phakic and 15 pseudophakic). All participants underwent SS-OCT imaging of the anterior segment, including measurements of the ITC index and ITC area.
BMC Ophthalmol
March 2025
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute, School of Optometry, Tianjin Medical University Eye Hospital, No. 251, Fukang Road, Nankai District, Tianjin, 30384, China.
Objective: To analyze the characteristics of anterior segment biometric parameters in moderate, high, and super-high myopia eyes for ICL size selection.
Methods: A total of 246 eyes of 131 patients were included in this prospective observational cohort study. Preoperative axis length (AL), central keratometry (Kc), central corneal thickness (CCT), white-to-white (WTW), internal anterior chamber depth (ACD), trabecular iris angle (TIA), anterior chamber width (ACW), angle-to-angle distance (ATA), crystalline lens rise (CLR), lens thickness (LT), sulcus-to-sulcus (STS), ICL size, and postoperative vault at 1 month were recorded and compared among the different degrees of myopia groups.
Br J Ophthalmol
February 2025
University eye clinic, Ruhr-University Bochum, Bochum, Germany
Aims: Refractive lens exchange (RLE) is becoming a popular refractive solution for patients ineligible for corneal surgeries or phakic intraocular lenses. However, concerns regarding retinal detachment (RD) risk persist.
Methods: A systematic literature review and meta-analysis was performed in Medline and Scopus.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!