This study aimed to evaluate the effect of glycolic acid (GA) as a chelating agent on the removal of smear layers and the microhardness of root dentin. This review followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, and study quality was assessed using a modified Joanna Briggs Institute (JBI) tool. Two authors independently conducted an electronic search across four databases, supplemented by examining the reference lists of the included articles. A total of five in-vitro studies having variable concentrations (5%, 10%, and 17%) of GA were chosen for this review. Two articles include microhardness and smear layer removal together, two deal with microhardness, and one deals with smear layer removal. The included studies revealed a low overall risk of bias owing to the variability among the studies; the analysis was limited to qualitative assessment, with no meta-analysis performed. Based on the findings, various concentrations of GA (5%, 10%, and 17%) can be considered alternatives for smear layer removal with less impact on root dentin microhardness. However, further studies with proper standardization are required to confirm the effects on root dentin.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11878687PMC
http://dx.doi.org/10.4103/JCDE.JCDE_679_24DOI Listing

Publication Analysis

Top Keywords

smear layer
16
layer removal
16
root dentin
12
glycolic acid
8
acid chelating
8
chelating agent
8
microhardness root
8
concentrations 10%
8
10% 17%
8
smear
5

Similar Publications

This study aimed to evaluate the effect of glycolic acid (GA) as a chelating agent on the removal of smear layers and the microhardness of root dentin. This review followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, and study quality was assessed using a modified Joanna Briggs Institute (JBI) tool. Two authors independently conducted an electronic search across four databases, supplemented by examining the reference lists of the included articles.

View Article and Find Full Text PDF

Unlabelled: This study evaluated thin-layer agar (TLA) as a faster alternative for both indirect minimum inhibitory concentration (MIC) determination of bedaquiline (BDQ) from culture isolates and direct drug-susceptibility testing (DST) from sputum samples. Indirect BDQ-MIC results from TLA were compared to the established 7H11 solid DST. Direct-TLA-DST performance was assessed using 143 baseline sputum samples from rifampicin-resistant TB cases.

View Article and Find Full Text PDF

Background: Chelating agents used to remove the inorganic part of the smear layer from prepared canals can alter dentin mineral composition, potentially affecting the adhesion of resin-based root canal cement and sealers.

Aim: This study aimed to compare the decalcifying effects of 17% ethylenediaminetetraacetic acid (EDTA), 20% N-acetyl cysteine (NAC), and deionized water (control) on root canal dentin using energy-dispersive X-ray spectroscopy (EDXS).

Materials And Methods: Sixty-nine extracted human mandibular premolars were randomly divided into three groups, yielding 138 root halves treated with either 17% EDTA, 20% NAC, or a control solution (n = 46).

View Article and Find Full Text PDF

Aim: This study aims to assess the effectiveness of silver-graphene oxide (AgGO) nanoparticles against Enterococcus faecalis biofilm and smear layer in comparison with 3% sodium hypochlorite (NaOCl) and 2% chlorhexidine (CHX) using passive ultrasonic irrigation (PUI) technique.

Subjects And Methods: Eighty single-rooted teeth were collected, sterilized, and prepared for this study. E.

View Article and Find Full Text PDF

Aim: Evaluation of root-end cavities for the existence of microcracks and smear layer with laser, ultrasonic tip by conventional bur, and control group in single-rooted tooth by scanning electron microscope (SEM).

Methodology: Fifty-two extracted fully developed single-rooted teeth were decoronated, cleaned, shaped, and obturated with F2 GP, and 3 mm roots were removed. Laser, ultrasonic tip (AS 3Dretro-tip on Newtron-SATELEC, Acteon), and conventional bur (size 010 round) were used to create root-end preparation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!