Background: Hemodialysis (HD) is associated with adverse cardiovascular events after percutaneous coronary intervention (PCI). Although the ultrathin strut biodegradable polymer sirolimus-eluting stent (ultrathin strut BP-SES) has had better results in patients undergoing PCI compared with other drug-eluting stents (DES), its usefulness in HD patients is unknown.
Methods And Results: This study involved 286 lesions in 162 HD patients who underwent PCI with a DES between January 2018 and June 2022. The incidence of clinically driven target lesion revascularization (TLR), target vessel failure (TVF: cardiac death, target vessel MI and clinically driven target vessel revascularization [TVR]) was assessed. During a median 636 days, clinically driven TLR occurred in 32 lesions. Clinically driven TLR at 2 years was significantly lower in the ultrathin strut BP-SES group than in the other DES group (2.9% vs. 17.3%, log-rank P=0.028). TVF occurred in 43 patients. The cumulative incidence of TVF was not different between two groups; however, clinically driven TVR was significantly lower in patients treated with the ultrathin strut BP-SES than with other DES (4.5% vs. 25.7%, log-rank P=0.027). In the quantitative coronary angiography analysis, late lumen loss at follow-up was significantly smaller in the ultrathin strut BP-SES group (0.13±0.40 vs. 0.67±1.02 mm, P<0.001).
Conclusions: In patients on HD undergoing PCI, the incidence of clinically driven TLR was significantly lower in ultrathin strut BP-SES compared to other DES.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1253/circj.CJ-24-0589 | DOI Listing |
Background: Hemodialysis (HD) is associated with adverse cardiovascular events after percutaneous coronary intervention (PCI). Although the ultrathin strut biodegradable polymer sirolimus-eluting stent (ultrathin strut BP-SES) has had better results in patients undergoing PCI compared with other drug-eluting stents (DES), its usefulness in HD patients is unknown.
Methods And Results: This study involved 286 lesions in 162 HD patients who underwent PCI with a DES between January 2018 and June 2022.
Am J Cardiol
January 2025
Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Suita, Japan.
A dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo Stent (DTS) has been developed to enhance endothelization and capture endothelial progenitor cells; however, vessel responses following DTS implantation remain unclear. Therefore, we evaluated early- and mid-term intravascular characteristics of DTS using intravascular imaging modalities. This multicenter, prospective, observational study enrolled 88 patients (95 lesions) who underwent DTS (43 patients, 48 lesions) or sirolimus-eluting Orsiro stent (SES, 45 patients, 47 lesions) implantation.
View Article and Find Full Text PDFClin Cardiol
December 2024
Division of Cardiology, Department of Internal Medicine, Yonsei University Wonju College of Medicine, Wonju, South Korea.
Background: The Orsiro and Genoss DES stents are biodegradable polymer drug-eluting stents (DESs) with ultrathin struts.
Objective: To investigate the safety and efficacy of these two ultrathin DESs in real-world practice.
Methods: From a single-center prospective registry, we included 751 and 931 patients treated with the Genoss DES and Orsiro stents, respectively.
Future Cardiol
January 2025
Internal Medicine Department, Division of Invasive Cardiology, University of Szeged, Szeged, Hungary.
Objectives: Data about coronary bifurcations treated with ultrathin strut drug-eluting stents (DES) using T-and-protrusion (TAP) technique is limited.
Methods: In this study, a total of 84 consecutive patients, who underwent bifurcation percutaneous coronary intervention (PCI) with TAP technique using Orsiro® DES (Biotronik, Berlin, Germany), were included. All pre- and post-procedural data, as well as 1- and 2-year follow-up angiograms, were analyzed.
Objectives: Current thin-strut 2 generation drug eluting stents (DES) are considered as optimal standard of care for revascularization of coronary artery disease (CAD) patients undergoing percutaneous coronary intervention (PCI). Ultrathin (≤ 70 μm strut thickness) strut DES have recently been shown to reduce target lesion failure (TLF) compared to thin-strut DES. Therefore, in order to assess the validity of improved outcomes associated with ultrathin-strut DES, we conducted an updated meta-analysis that includes recently published follow-ups of previously conducted randomized controlled trials (RCTs).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!