Background: Hemodialysis (HD) is associated with adverse cardiovascular events after percutaneous coronary intervention (PCI). Although the ultrathin strut biodegradable polymer sirolimus-eluting stent (ultrathin strut BP-SES) has had better results in patients undergoing PCI compared with other drug-eluting stents (DES), its usefulness in HD patients is unknown.

Methods And Results: This study involved 286 lesions in 162 HD patients who underwent PCI with a DES between January 2018 and June 2022. The incidence of clinically driven target lesion revascularization (TLR), target vessel failure (TVF: cardiac death, target vessel MI and clinically driven target vessel revascularization [TVR]) was assessed. During a median 636 days, clinically driven TLR occurred in 32 lesions. Clinically driven TLR at 2 years was significantly lower in the ultrathin strut BP-SES group than in the other DES group (2.9% vs. 17.3%, log-rank P=0.028). TVF occurred in 43 patients. The cumulative incidence of TVF was not different between two groups; however, clinically driven TVR was significantly lower in patients treated with the ultrathin strut BP-SES than with other DES (4.5% vs. 25.7%, log-rank P=0.027). In the quantitative coronary angiography analysis, late lumen loss at follow-up was significantly smaller in the ultrathin strut BP-SES group (0.13±0.40 vs. 0.67±1.02 mm, P<0.001).

Conclusions: In patients on HD undergoing PCI, the incidence of clinically driven TLR was significantly lower in ultrathin strut BP-SES compared to other DES.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.CJ-24-0589DOI Listing

Publication Analysis

Top Keywords

ultrathin strut
24
clinically driven
20
strut bp-ses
16
target vessel
12
strut biodegradable
8
biodegradable polymer
8
polymer sirolimus-eluting
8
percutaneous coronary
8
coronary intervention
8
driven target
8

Similar Publications

Background: Hemodialysis (HD) is associated with adverse cardiovascular events after percutaneous coronary intervention (PCI). Although the ultrathin strut biodegradable polymer sirolimus-eluting stent (ultrathin strut BP-SES) has had better results in patients undergoing PCI compared with other drug-eluting stents (DES), its usefulness in HD patients is unknown.

Methods And Results: This study involved 286 lesions in 162 HD patients who underwent PCI with a DES between January 2018 and June 2022.

View Article and Find Full Text PDF

A dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo Stent (DTS) has been developed to enhance endothelization and capture endothelial progenitor cells; however, vessel responses following DTS implantation remain unclear. Therefore, we evaluated early- and mid-term intravascular characteristics of DTS using intravascular imaging modalities. This multicenter, prospective, observational study enrolled 88 patients (95 lesions) who underwent DTS (43 patients, 48 lesions) or sirolimus-eluting Orsiro stent (SES, 45 patients, 47 lesions) implantation.

View Article and Find Full Text PDF

Background: The Orsiro and Genoss DES stents are biodegradable polymer drug-eluting stents (DESs) with ultrathin struts.

Objective: To investigate the safety and efficacy of these two ultrathin DESs in real-world practice.

Methods: From a single-center prospective registry, we included 751 and 931 patients treated with the Genoss DES and Orsiro stents, respectively.

View Article and Find Full Text PDF

Objectives: Data about coronary bifurcations treated with ultrathin strut drug-eluting stents (DES) using T-and-protrusion (TAP) technique is limited.

Methods: In this study, a total of 84 consecutive patients, who underwent bifurcation percutaneous coronary intervention (PCI) with TAP technique using Orsiro® DES (Biotronik, Berlin, Germany), were included. All pre- and post-procedural data, as well as 1- and 2-year follow-up angiograms, were analyzed.

View Article and Find Full Text PDF

Objectives: Current thin-strut 2 generation drug eluting stents (DES) are considered as optimal standard of care for revascularization of coronary artery disease (CAD) patients undergoing percutaneous coronary intervention (PCI). Ultrathin (≤ 70 μm strut thickness) strut DES have recently been shown to reduce target lesion failure (TLF) compared to thin-strut DES. Therefore, in order to assess the validity of improved outcomes associated with ultrathin-strut DES, we conducted an updated meta-analysis that includes recently published follow-ups of previously conducted randomized controlled trials (RCTs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!