A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of Cone-Beam Computed Tomography Voxel Size on the Accuracy of Periodontal Ligament Surface Area Measurements. | LitMetric

Objective: Accurate assessment of the periodontal ligament (PDL) is critical for developing effective treatment plans in periodontics, orthodontics, prosthodontics, and maxillofacial surgical. This study aimed to investigate the influence of cone-beam computed tomography (CBCT) voxel size (0.3 and 0.1 mm) on the accuracy of PDL surface area measurements.

Methods: Thirty-nine teeth, including both single-rooted and multirooted types, were obtained from 5 human skulls and imaged using CBCT and high-resolution computed tomography (CT). The PDL was segmented and reconstructed using Mimics and 3-matic software to determine surface area measurements. Statistical analyses included paired t tests (P<0.05) to identify significant differences and Bland-Altman plots to evaluate agreement between measurements obtained at different voxel sizes.

Results: Paired t tests demonstrated a statistically significant difference in PDL surface area measurements based on voxel size (t=4.959, P=0.001). Bland-Altman analysis revealed that measurements obtained with a voxel size of 0.1 mm were, on average, 5.07 mm² larger than those obtained with a voxel size of 0.3 mm.

Conclusions: Voxel size significantly affects the precision of PDL surface area measurements, with smaller voxels yielding greater surface detail and higher surface area values. High-resolution CT provided more accurate and reliable measurements of PDL surface area compared with CBCT.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0000000000011179DOI Listing

Publication Analysis

Top Keywords

computed tomography
12
surface area
12
influence cone-beam
8
cone-beam computed
8
voxel size
8
periodontal ligament
8
area measurements
8
tomography voxel
4
size accuracy
4
accuracy periodontal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!