A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Toxicokinetic Characterization of Isopropyl Glycidyl Ether in Rat by a Validated LC-APCI-MS/MS Method Using In-Source Derivatization. | LitMetric

Isopropyl glycidyl ether (IPGE) is a member of the large glycidyl ether family frequently used as a reactive diluent during the epoxy resin manufacturing process. Although the toxicity induced by this type of chemical has been investigated in many studies of different aspects (acute, subchronic, genotoxic, reproduction, etc.), there is still little known about their toxicokinetics. To gain information about the attainable systemic concentration, a liquid chromatography─tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of IPGE in rat plasma using its structural analogue -butyl glycidyl ether as the internal standard. Two types of atmospheric pressure ionization techniques have been utilized; however, the protonated molecule ion could not be observed in either ionization mode. First, the ammonium adduct form was used for fragmentation, albeit this multiple-reaction monitoring transition proved to be not sensitive enough for real study sample analysis. In order to achieve the desired sensitivity, the Meerwein reaction was applied as an in-source derivatization tool to generate a product by using the ethylnitrilium ion formed from the eluent acetonitrile. This gas-phase reaction enabled us to build up a method with a substantial sensitivity increase (LLOQ of 0.01 μg/mL) compared to that obtained with the ammonium adduct. After method validation, real study samples from a single-dose oral toxicity study were analyzed to evaluate the blood plasma concentration of IPGE at three dose levels. Dose-dependent superproportional systemic exposure was observed in the studied dose range (1000-2000 mg/kg). Additionally, seven metabolites of IPGE were tentatively identified in rat plasma: 3-isopropoxy-2-hydroxy-1-propanol (M1), sulfate-conjugate of IPGE (M3), glucuronide-conjugate of IPGE (M4), 3-isopropoxy-2-hydroxypropionic acid (M5), -isopropyl--acetylserine (M6), -(2-hydroxy-isopropyl)--acetylserine (M7), and glutathione-conjugate of IPGE (M11). Present work may pave the way to other methods that are able to quantify compounds similar to IPGE even in human plasma, which could provide valuable information to assist exposure assessment and biomonitoring in occupational health and safety studies.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.chemrestox.4c00376DOI Listing

Publication Analysis

Top Keywords

glycidyl ether
16
isopropyl glycidyl
8
in-source derivatization
8
ipge
8
rat plasma
8
ammonium adduct
8
real study
8
toxicokinetic characterization
4
characterization isopropyl
4
glycidyl
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!