A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Low-Rank Constrained Reacquired-Navigator Reconstruction of multi-shot DWI. | LitMetric

The Diffusion-Weighted Imaging (DWI) requires additional acquisition of phase correction data and parallel imaging prescan data to respectively suppress artifacts caused by odd-even echo errors and motion-induced phase errors. In this study, we propose subtle modifications to the widely used spin-echo DW sequence, wherein an additional 180° radiofrequency refocusing pulse is applied after the completion of image echoes to acquire fully sampled navigator-echo data. Our proposed approach draws parallels with the dual spin-echo DW technique. However, our methodology distinguishes itself by utilizing positive and negative gradients to independently capture fully sampled navigator-echo data. Following this, we employ algorithms grounded in low-rank constraints, in conjunction with the reacquired navigator-echo data to address the two major phase errors inherent in Multi-Shot DWI (MSDWI). Simulation studies and in vivo brain imaging experiments demonstrate that this approach effectively suppresses image artifacts caused by the phase error, without the need for additional time-consuming prescans.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC53108.2024.10782950DOI Listing

Publication Analysis

Top Keywords

navigator-echo data
12
multi-shot dwi
8
artifacts caused
8
phase errors
8
fully sampled
8
sampled navigator-echo
8
data
5
low-rank constrained
4
constrained reacquired-navigator
4
reacquired-navigator reconstruction
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!