A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Remote Super-Resolution Mapping of Wave Fields. | LitMetric

Remote Super-Resolution Mapping of Wave Fields.

IEEE Trans Ultrason Ferroelectr Freq Control

Published: February 2025

Mapping wave field in space has many applications such as optimizing design of radio antennas, improving and developing ultrasound transducers, and planning and monitoring the treatment of tumors using high-intensity focused ultrasound (HIFU). Currently, there are methods that can map wave fields remotely or locally. However, there are limitations with these methods. For example, when mapping the wave fields remotely, the spatial resolution is limited due to a poor diffractionlimited resolution of the receiver, especially when the f-number of the receiver is large. To map the wave fields locally, the receiver is either subject to damage in hazardous environments (corrosive media, high temperature, and high wave intensity, etc) or difficult to be placed inside an object. To address these limitations, in this paper, the PSF-modulation super-resolution imaging method (January, 2024 IEEE TUFFC) was applied to map pulse ultrasound wave fields remotely at a high spatial resolution, overcoming the diffraction limit of a focused receiver. For example, to map a pulse ultrasound field of a full-width-at-half-maximum (FWHM) beam width of 1.24 mm at the focal distance of a transmitter, the FWHM beam widths of the super-resolution mapping of the pulse wave field with a spherical glass modulator of 0.7-mm diameter at two receiver angles (0° and 45°) were about 1.13 mm and 1.22 mm respectively, which were close to the theoretical value of 1.24 mm and were much smaller than the diffraction-limited resolution (1.81 mm) of the receiver. Without using the super-resolution method to remotely map the same pulse wave field, the FWHM beam width was about 2.06 mm. For comparison, the FWHM beam width obtained with a broadband (1-20 MHz) and 0.6-mm diameter polyvinylidene fluoride (PVDF) needle hydrophone was about 1.41 mm. In addition to the focused pulse ultrasound wave field, a pulse Bessel beam near the transducer surface was mapped remotely with the super-resolution method, which revealed high spatial frequency components of the beam.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2025.3538607DOI Listing

Publication Analysis

Top Keywords

wave fields
20
wave field
16
fwhm beam
16
mapping wave
12
fields remotely
12
map pulse
12
pulse ultrasound
12
beam width
12
wave
10
super-resolution mapping
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!