The formation of a new head during Hydra regeneration involves the establishment of a head organizer that functions as a signaling center and contains an aster-shaped topological defect in the organization of the supracellular actomyosin fibers. Here, we show that the future head region in regenerating tissue fragments undergoes multiple instances of extensive stretching and rupture events from the onset of regeneration. These recurring localized tissue deformations arise due to transient contractions of the supracellular ectodermal actomyosin fibers that focus mechanical strain at defect sites. We further show that stabilization of aster-shaped defects is disrupted by perturbations of the Wnt signaling pathway. We propose a closed-loop feedback mechanism promoting head organizer formation, and develop a biophysical model of regenerating Hydra tissues that incorporates a morphogen source activated by mechanical strain and an alignment interaction directing fibers along morphogen gradients. We suggest that this positive-feedback loop leads to mechanical strain focusing at defect sites, enhancing local morphogen production and promoting robust organizer formation.

Download full-text PDF

Source
http://dx.doi.org/10.1242/dev.204514DOI Listing

Publication Analysis

Top Keywords

mechanical strain
16
defect sites
12
strain focusing
8
topological defect
8
regenerating hydra
8
head organizer
8
actomyosin fibers
8
organizer formation
8
mechanical
4
focusing topological
4

Similar Publications

Multidrug resistance (MDR) infectious wounds are a major concern due to drug resistance, leading to increased patient morbidity. Lichenysin (LCN), a lipopeptide and biosurfactant obtained from certain strains of , has demonstrated an excellent antimicrobial property. The present study focuses on the fabrication and comprehensive evaluation of LCN-incorporated poly(vinyl alcohol) (PVA)/polycaprolactone (PCL)-based nanofiber scaffolds using an electrospinning technique as a potential wound healing biomaterial for the treatment of MDR infectious wounds in diabetic rats.

View Article and Find Full Text PDF

Flexible microcolumn array-based silk fibroin for sweat glucose monitoring.

Anal Chim Acta

May 2025

College of Textile Science and Engineering, Jiangnan University, 1800Lihu Road, Wuxi, 214122, China. Electronic address:

Flexible sweat sensors possess the special potential for continuous non-invasive monitoring of human blood glucose. We put forward a flexible microcolumn array sensor, which is designed for health monitoring by means of detecting glucose levels in sweat and capturing physiological signals related to human movement. With the combination of silk fibroin (SF), waterborne polyurethane (PU), and multi-walled carbon nanotubes (MWCNT), this microcolumn film electrode is able to effectively function as a strain sensor benefiting from the superior mechanical performance of PU.

View Article and Find Full Text PDF

Purpose: Central hypovolemia is considered to lead to a compensatory increase in cardiac contractility. From a physiological perspective, left ventricular (LV) twisting motion, which plays an important role in maintaining cardiac output, should be enhanced during central hypovolemia, but previous studies have shown inconsistent findings. Using 3D echocardiography, we tested the hypothesis that the LV twisting and untwisting motion would be enhanced during severe central hypovolemia.

View Article and Find Full Text PDF

As shale gas is an unconventional energy source, it is believed to be essential for achieving green resource development and improving the energy supply-demand balance. However, owing to shale's substantial anisotropic properties and various microstructures, its gas flow characteristics and transport mechanisms are exceedingly complex. Therefore, accurately predicting gas permeability evolution in shale pores was considered to be important for energy development.

View Article and Find Full Text PDF

Purpose: In patients with repaired tetralogy of Fallot, transcatheter or surgical pulmonary valve replacement is recommended. However, it is not clear whether pulmonary valve replacement preserves systolic and diastolic functions of both ventricles. The aim of the study is to investigate the impact of transcatheter pulmonary valve replacement on atrial and ventricular myocardial strain changes by feature-tracking cardiac magnetic resonance imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!