A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of a whole blood coagulometer sensitive to the direct oral anticoagulants. | LitMetric

Readily available and rapid turn-around, bedside assays to measure the effect of the direct oral anticoagulants (DOACs) are not available. This study evaluates a point-of-care (PoC) coagulometer to assess the anticoagulant effects of the DOACs and low molecular weight heparin. Studies were done in fresh spiked blood from healthy volunteers. PoC coagulometer baseline clotting times were half that of the manual whole blood clotting time (WBCT, legacy method) and exhibited a sensitivity to DOAC anticoagulation approximately twice that of WBCT. All %CV values for both methods were < 10% with most being < 5% indicating acceptable precision of both methods. R values for both clotting time and percent rise from baseline were > 0.98 indicating a strong correlation between the two methods. Replicate measurements for all subjects showed a maximum upper %CV value of 5.56% and a maximum upper value of all absolute %Differences of 5.5%, with both criteria meeting predefined acceptance criteria. The dose-response curves for all subjects were linear across the concentration ranges tested. The Perosphere Technology PoC coagulometer detects a range of therapeutic levels of the DOACs apixaban, rivaroxaban, edoxaban, and dabigatran, as well as the low molecular weight heparin, enoxaparin, with high precision and sensitivity. Please check and confirm the processed affiliations are correct . and amend if necessary.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11873143PMC
http://dx.doi.org/10.1038/s41598-025-92201-7DOI Listing

Publication Analysis

Top Keywords

direct oral
8
oral anticoagulants
8
poc coagulometer
8
validation blood
4
blood coagulometer
4
coagulometer sensitive
4
sensitive direct
4
anticoagulants rapid
4
rapid turn-around
4
turn-around bedside
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!