Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Readily available and rapid turn-around, bedside assays to measure the effect of the direct oral anticoagulants (DOACs) are not available. This study evaluates a point-of-care (PoC) coagulometer to assess the anticoagulant effects of the DOACs and low molecular weight heparin. Studies were done in fresh spiked blood from healthy volunteers. PoC coagulometer baseline clotting times were half that of the manual whole blood clotting time (WBCT, legacy method) and exhibited a sensitivity to DOAC anticoagulation approximately twice that of WBCT. All %CV values for both methods were < 10% with most being < 5% indicating acceptable precision of both methods. R values for both clotting time and percent rise from baseline were > 0.98 indicating a strong correlation between the two methods. Replicate measurements for all subjects showed a maximum upper %CV value of 5.56% and a maximum upper value of all absolute %Differences of 5.5%, with both criteria meeting predefined acceptance criteria. The dose-response curves for all subjects were linear across the concentration ranges tested. The Perosphere Technology PoC coagulometer detects a range of therapeutic levels of the DOACs apixaban, rivaroxaban, edoxaban, and dabigatran, as well as the low molecular weight heparin, enoxaparin, with high precision and sensitivity. Please check and confirm the processed affiliations are correct . and amend if necessary.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11873143 | PMC |
http://dx.doi.org/10.1038/s41598-025-92201-7 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!