BACKGROUND Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) is increasingly used, as older high-risk patient populations require repeat aortic valve replacements. The most common approach to ViV-TAVR is through a transfemoral approach or alternative vascular access sites, such as transcarotid or transsubclavian TAVR. Within this population, some patients become ineligible for ViV-TAVR due to contraindications, such as severe peripheral vascular disease, necessitating an alternative. Transapical TAVR allows for TAVR even in the context of severe peripheral vascular disease, although it has rarely been used in the ViV-TAVR setting, and even less frequently with concomitant percutaneous coronary intervention. CASE REPORT We present the case of a 79-year-old man with a history of coronary artery disease and aortic valve disease 9 years after coronary artery bypass grafting and aortic valve replacement presenting with progressive dyspnea on exertion. The patient was found to have severe prosthetic valve degeneration but had a high preoperative surgical risk score and severe peripheral arterial disease. Transfemoral, carotid, and subclavian access were contraindicated given the severe vascular disease, and therefore the patient underwent transapical ViV-TAVR with a 26-mm Sapien S3 valve and a left main coronary artery snorkel stent for protection of the left main coronary. CONCLUSIONS With this rare documented case of transapical ViV-TAVR, we highlight the importance of having several available alternative surgical approaches to TAVR for patients who are ineligible for transfemoral ViV-TAVR and have high preoperative risk scores.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11885597PMC
http://dx.doi.org/10.12659/AJCR.946582DOI Listing

Publication Analysis

Top Keywords

aortic valve
20
valve replacement
12
severe peripheral
12
vascular disease
12
coronary artery
12
transcatheter aortic
8
concomitant percutaneous
8
percutaneous coronary
8
coronary intervention
8
intervention case
8

Similar Publications

Aortic valve stenosis (AVS) is a progressive disease, wherein males more often develop valve calcification relative to females that develop valve fibrosis. Valvular interstitial cells (VICs) aberrantly activate to myofibroblasts during AVS, driving the fibrotic valve phenotype in females. Myofibroblasts further differentiate into osteoblast-like cells and produce calcium nanoparticles, driving valve calcification in males.

View Article and Find Full Text PDF

Successful Percutaneous Extraction of a WATCHMAN FLX Device From the Left Ventricular Outflow Tract.

JACC Case Rep

January 2025

Division of Cardiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA. Electronic address:

Background: Although rare, embolization of left atrial appendage occlusion (LAAO) devices carries a significant morbidity and mortality burden.

Case Summary: An asymptomatic 77-year-old woman with inability to tolerate anticoagulation due to gastrointestinal bleeding presented for 45-day transesophageal echocardiography following LAAO with a Watchman device, which demonstrated incidental device migration to the left ventricular outflow tract (LVOT). Percutaneous extraction was performed using a novel technique with rat tooth/alligator forceps to successfully retrieve the Watchman from the LVOT using a transaortic approach.

View Article and Find Full Text PDF

Background: Acute Stanford type A aortic dissection is a severe emergency condition that, if left untreated, is associated with a high mortality rate. The extent of surgical repair may impact the outcomes of these patients.

Method: Patients operated for acute type A aortic dissection from a multicentre European registry were included.

View Article and Find Full Text PDF

Deep Learning-Based Contrast Boosting in Low-Contrast Media Pre-TAVR CT Imaging.

Can Assoc Radiol J

March 2025

Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

This study investigates the impact of deep learning-based contrast boosting (DL-CB) on image quality and measurement reliability in low-contrast media (low-CM) CT for pre-transcatheter aortic valve replacement (TAVR) assessment. This retrospective study included TAVR candidates with renal dysfunction who underwent low-CM (30-mL: 15-mL bolus of contrast followed by 50-mL of 30% iomeprol solution) pre-TAVR CT between April and December 2023, along with matched standard-CM controls (n = 68). Low-CM images were reconstructed as conventional, 50-keV, and DL-CB images.

View Article and Find Full Text PDF

Background: The development of aortic valve regurgitation (AR) negatively affects the survival of patients with continuous-flow left ventricular assist device (LVAD) support. Although several risk factors have been identified, little is known about the effect of preoperative aortic root and valve morphology on the development of de novo AR after LVAD implantation.

Methods: Between April 2018 and September 2023, 87 patients underwent durable LVAD implantation at our department.

View Article and Find Full Text PDF