The feasibility of a novel 'magnetic arch' topology for controlled contactless plasma beam acceleration is experimentally demonstrated using a pair of coaxial electron cyclotron resonance sources with opposing magnetic polarities, such that their respective magnetic nozzles connect to form a closed-line configuration. Retarding potential analyser measurements are taken for a single source and the two sources with the same and opposing polarities, as well as no applied magnetic field, showing that the magnetic arch yields higher maximum ion current and lower plume divergence angle than other alternative configurations, albeit the most probable ion energy is lower than for a single magnetic nozzle, in agreement with existing models. This validation paves the way to clustering magnetic-nozzle-based plasma thrusters for space propulsion.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11861235 | PMC |
http://dx.doi.org/10.1007/s44205-025-00100-w | DOI Listing |
Angew Chem Int Ed Engl
March 2025
Beijing University of Chemical Technology, State Key Laboratory of Chemical Resource Engineering, CHINA.
Incompatible electrode/electrolyte interface often leads to dendrite growth, parasitic reactions and corrosion, posing significant challenges to the application of Zn anodes. Herein, we introduce a biomimetic antifreeze protein localized gel electrolyte (ALGE) with multifunctional capabilities to address these issues by combining electrolyte modification with interface optimization. ALGE modifies the Zn2+ solvation structure and the hydrogen-bond network adjacent to zinc anode, effectively suppressing hydrogen evolution.
View Article and Find Full Text PDFChem Pharm Bull (Tokyo)
March 2025
Faculty of Pharmacy, Kindai University, 3-4-1 Kowakae, Higashi-Osaka, Osaka 577-8502, Japan.
In the present study, magnetic-calcined bamboo composite adsorbents (MCBC200, MCBC400, MCBC600, MCBC800, and MCBC1000) were prepared, and their physicochemical characteristics (scanning electron microscope images, differential thermogravimetric analysis, Fourier transform-IR, specific surface area, surface functional groups, and point of zero charge [pH]) were evaluated. Furthermore, the adsorption capacity of methylene blue (MB, cationic dye) using the prepared adsorbents was assessed. The value of pH and the specific surface area of MCBC400 were 7.
View Article and Find Full Text PDFJ Biol Chem
March 2025
Department of Biological Sciences, University of Pittsburgh, Pittsburgh, PA, USA. Electronic address:
The potassium chloride co-transporter 2 (KCC2) is required for neuronal development, and KCC2 dysregulation is implicated in several neurodevelopmental disorders, including schizophrenia, autism, and epilepsy. A dozen mutations in the KCC2-encoding gene, SLC12A5, are associated with these disorders, but few are fully characterized. To this end, we examined KCC2 biogenesis in a HEK293 cell model.
View Article and Find Full Text PDFFood Chem
March 2025
University of Lodz, Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, Electrochemistry@Soft Interface Team, Tamka 12, 91-403 Łódź, Poland.
This paper presents an electrochemical approach to quantitative and qualitative determination of hordenine (HODE) at the electrified liquid-liquid interface (eLLI). In this regard, we have employed ion transfer voltammetry (ITV) as an electroanalytical detection technique. The response of peak current values (positive or negative currents) increased linearly with HODE concentration in the studied concentration range from 28.
View Article and Find Full Text PDFACS Appl Mater Interfaces
March 2025
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China.
Phosphorus is considered an ideal anode material for lithium ion storage by virtue of its high theoretical capacity and moderate lithiation potential. However, issues such as large volume expansion of phosphorus leading to an electrical loss of contact and instability of the solid electrolyte interface hinder its practical performance. Improvement strategies that can effectively suppress volume expansion and provide stable electrical contacts are urgently needed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!