Aims: To demonstrate pharmacokinetic equivalence of CT‑P39 administered via auto-injector (CT‑P39 AI) and European Union-approved reference omalizumab via pre-filled syringe (EU-OMA PFS) in healthy Japanese adults.

Participants & Methods: This open-label, Phase 1 study randomized participants (1:1) to a single 150 mg/mL dose of CT‑P39 AI or EU-OMA PFS. The primary endpoint was pharmacokinetic equivalence per area under the concentration-time curve from time zero to infinity (AUC) and maximum serum concentration (C). Equivalence was concluded if the 90% confidence intervals (CIs) for the ratios of geometric least-squares means (gLSMs) were contained within the predefined 80-125% equivalence margin. Secondary endpoints comprised additional pharmacokinetics, pharmacodynamics, safety, and immunogenicity.

Results: Overall, 65 and 64 individuals were randomized to CT‑P39 AI and EU-OMA PFS, respectively. Pharmacokinetic equivalence between CT‑P39 AI and EU-OMA PFS was demonstrated for both AUC (ratio of gLSMs [90% CI] 101.66 [95.31-108.45]) and C (93.91 [87.20-101.14]). Thirty-nine (60.0%; CT‑P39 AI) and 32 (50.8%; EU-OMA PFS) participants experienced treatment-emergent adverse events (TEAEs) with no serious TEAEs. Secondary endpoints were comparable between groups.

Conclusions: CT‑P39 AI was pharmacokinetically equivalent to EU-OMA PFS following a single dose in healthy Japanese individuals; pharmacodynamics, safety, and immunogenicity were comparable.

Download full-text PDF

Source
http://dx.doi.org/10.1080/1750743X.2025.2467026DOI Listing

Publication Analysis

Top Keywords

eu-oma pfs
24
pharmacokinetic equivalence
12
ct‑p39 eu-oma
12
ct‑p39
8
reference omalizumab
8
omalizumab pre-filled
8
pre-filled syringe
8
equivalence ct‑p39
8
healthy japanese
8
secondary endpoints
8

Similar Publications

Aims: To demonstrate pharmacokinetic equivalence of CT‑P39 administered via auto-injector (CT‑P39 AI) and European Union-approved reference omalizumab via pre-filled syringe (EU-OMA PFS) in healthy Japanese adults.

Participants & Methods: This open-label, Phase 1 study randomized participants (1:1) to a single 150 mg/mL dose of CT‑P39 AI or EU-OMA PFS. The primary endpoint was pharmacokinetic equivalence per area under the concentration-time curve from time zero to infinity (AUC) and maximum serum concentration (C).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!