Background: This study compares the association between real-time continuous glucose monitoring (rtCGM) and intermittently- scanned CGM (isCGM) and glycemic control in individuals with type 1 diabetes mellitus (T1DM) in a real-world setting.

Methods: Using data from the Korean National Health Insurance Service Cohort, individuals with T1DM managed by intensive insulin therapy were followed at 3-month intervals for 2 years after the initiation of CGM. The glycosylated hemoglobin (HbA1c) levels and coefficients of variation (CVs) of rtCGM and isCGM users were compared using independent two-sample t-test and a linear mixed model.

Results: The analyses considered 7,786 individuals (5,875 adults aged ≥19 years and 1,911 children and adolescents aged <19 years). Overall, a significant reduction in HbA1c level was observed after 3 months of CGM, and the effect was sustained for 2 years. The mean HbA1c level at baseline was higher in rtCGM users than in isCGM users (8.9%±2.7% vs. 8.6%±2.2%, P<0.001). However, from 3 to 24 months, rtCGM users had lower HbA1c levels than isCGM users at every time point (7.1%±1.2% vs. 7.5%±1.3% at 24 months, P<0.001 for all time points). In both adults and children, the greater reduction in HbA1c with rtCGM remained significant after adjusting for the baseline characteristics of the users. The CV also showed greater decrease with rtCGM than with isCGM.

Conclusion: In this large nationwide cohort study, the use of rtCGM was associated with a greater improvement in glycemic control, including HbA1c reduction, than the use of isCGM in both adults and children with T1DM.

Download full-text PDF

Source
http://dx.doi.org/10.4093/dmj.2024.0160DOI Listing

Publication Analysis

Top Keywords

continuous glucose
8
glucose monitoring
8
glycemic control
8
type diabetes
8
diabetes mellitus
8
comparison real-time
4
real-time intermittently-scanned
4
intermittently-scanned continuous
4
monitoring glycemic
4
control type
4

Similar Publications

Flexible microcolumn array-based silk fibroin for sweat glucose monitoring.

Anal Chim Acta

May 2025

College of Textile Science and Engineering, Jiangnan University, 1800Lihu Road, Wuxi, 214122, China. Electronic address:

Flexible sweat sensors possess the special potential for continuous non-invasive monitoring of human blood glucose. We put forward a flexible microcolumn array sensor, which is designed for health monitoring by means of detecting glucose levels in sweat and capturing physiological signals related to human movement. With the combination of silk fibroin (SF), waterborne polyurethane (PU), and multi-walled carbon nanotubes (MWCNT), this microcolumn film electrode is able to effectively function as a strain sensor benefiting from the superior mechanical performance of PU.

View Article and Find Full Text PDF

We examined whether the glucose levels and awareness of individuals without diabetes changed after using a sensor-based intermittently scanned continuous glucose monitoring (isCGM) system in their daily lives. Japanese individuals without a diabetes diagnosis wore the isCGM system while maintaining a normal lifestyle during the baseline period. A certified diabetes educator coached them on how to improve their lifestyle based on information from sensor data, food journals, and body composition.

View Article and Find Full Text PDF

Background: Type 2 diabetes (T2D) is characterized by insulin resistance and defective insulin secretion. Previously, we found that rats fed soft pellets (SPs) on a 3-hour restricted schedule over 14 weeks demonstrated glucose intolerance and insulin resistance with disruption of insulin signaling.

Objective: To determine (1) the time required for an SP diet to induce insulin resistance, and (2) whether the metabolic derangements in rats fed SPs can be reversed by changing to a standard control diet.

View Article and Find Full Text PDF

Older Adults with Diabetes in Korea: Latest Clinical and Epidemiologic Trends.

Diabetes Metab J

March 2025

Division of Endocrinology and Metabolism, Department of Internal Medicine, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.

Backgruound: Diabetes in older adults is becoming a significant public burden to South Korea. However, a comprehensive understanding of epidemiologic trends and the detailed clinical characteristics of older adults with diabetes is lacking. Therefore, we evaluated epidemiologic trends and the metabolic and lifestyle characteristics of diabetes in Korean older adults.

View Article and Find Full Text PDF

Effects of the triglyceride-glucose index on non-alcoholic fatty liver disease: Causal evidence from longitudinal cohort studies.

Arch Gerontol Geriatr

March 2025

School of Public Health, Capital Medical University, NO. 10 Xitoutiao, Youanmenwai, Fengtai District, Beijing 100069, China. Electronic address:

Background: Insulin resistance (IR) is strongly related to non-alcoholic fatty liver disease (NAFLD). Triglyceride-glucose (TyG) index serves as a novel substitute indicator for IR. However, research on the effect of TyG index on NAFLD remains sparse.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!