Purpose: To compare AcrySof MA60AC (Alcon Laboratories, Fort Worth, TX, USA) and Sensar AR40e (Johnson and Johnson, Santa Ana, CA, USA) used in Yamane sutureless scleral fixation technique in terms of visual acuity, refractive stability, and complications.
Methods: A retrospective, cross-sectional study was conducted in Istanbul Başakşehir Çam and Sakura City Hospital. Patients were divided into two groups: The first group consisted of patients with MA60AC lenses, while the second group consisted of patients with AR40e. Aphakic patients who underwent secondary intraocular lens (IOL) implantation and had postoperative minimum 3-month follow-up records were included. Visual acuity, refractive outcomes, perioperative and postoperative complications were recorded.
Results: Forty-nine patients were included in the study. Twenty-two patients were in the first group and 27 patients were in the second group. Age, gender, and follow-up time were similar between groups (P = 0.546, 0.213, and 0.347, respectively). The median lenticular astigmatism value was 0.86 (0.08-2.11) D in group 1 and 0.99 (0.31-2.96) D in group 2 (P = 0.898). There was no significant difference between groups in terms of visual acuity, spherical, cylindrical, and spherical equivalent values (P = 0.752, 0.375, 0.073, and 0.949, respectively). In group 1, a haptic tip fracture and optic-haptic separation were observed perioperatively. Optic-haptic junction separation was observed in one patient in group 1 on postoperative day 1. In group 1, epiretinal membrane development was significantly higher (P = 0.019).
Conclusions: Both AcrySof MA60AC and Sensar AR40e IOLs via the modified Yamane technique yielded favorable and predictable outcomes. Although statistically insignificant, haptic problems were more common in the first group.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4103/IJO.IJO_2235_24 | DOI Listing |
J Glaucoma
March 2025
Department of Ophthalmology, National University Hospital, National University Health System.
Prcis: In this retrospective cohort study, the 1-year cumulative probability of failure was comparable, achieving 52.20% in the phacoemulsification-iStent inject W (phaco/iStent) group and 47.80% in the phacoemulsification-micropulse transscleral laser therapy (phaco/MPTLT) group (P=0.
View Article and Find Full Text PDFJ Mot Behav
March 2025
Kinesiology Department, University of Massachusetts Amherst, Massachusetts, USA.
Persistent contact sport participation exposes athletes to repetitive head impacts, eliciting lingering motor performance alterations that could disrupt visual perception. We sought to compare head and trunk displacement, segmental coordination, and dynamic visual acuity between contact (ice hockey) and noncontact (baseball) athletes. Thirteen ice hockey and 11 baseball athletes walked at preferred and fast speeds during both a baseline and an imposed dynamic visual acuity (DVA) task.
View Article and Find Full Text PDFJ Cataract Refract Surg
March 2025
Ophthalmology Unit, Centro Hospitalar Universitário de Coimbra (CHUC), Unidade Local de Saúde (ULS) de Coimbra, Portugal.
Purpose: To assess the real-life impact of preoperative visual simulations with SimVis Gekko (SVG) on predicting postoperative visual performance in patients undergoing bilateral cataract surgery with trifocal or extended depth of focus (EDOF) intraocular lenses (IOL).
Setting: Centro Hospitalar Universitário de Coimbra, Portugal.
Design: Single-center prospective observational cohort study.
J Cataract Refract Surg
March 2025
University Eye Clinic, Maastricht University Medical Center, The Netherlands.
Topic: To evaluate the efficacy of currently available digital and remote care applications for postoperative cataract management compared to traditional methods for postoperative clinical measurements.
Clinical Relevance: With the increasing demand for ophthalmological services and an anticipated shortage of professionals, innovative approaches are needed to optimize care. Cataract surgery, characterized by its high safety profile and turnover rate, is well-suited for digital and remote care solutions, which could enhance the postoperative patient pathway, potentially leading to substantial time and cost savings.
BMC Ophthalmol
March 2025
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-sen University, Guangzhou, 510060, China.
Purpose: To compare the refractive outcomes and visual quality among different types of astigmatism following SMILE and evaluate effective optical zone (EOZ) features, decentration and their potential effects on visual quality.
Methods: This study included 101 left eyes of 101 patients who underwent SMILE. Patients were grouped according to astigmatism types (with-the-rule [WTR], against-the-rule [ATR] and oblique astigmatism) and decentered displacement (major axis > minor axis and major axis < minor axis).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!