Microplastic (MP) pollution has recently emerged as a critical global environmental issue. Laundry wastewater is a significant contributor to MP pollution, containing high concentrations of MPs. Although coagulation has recently been widely applied to remove MPs from such wastewater, its efficiency remains poor, and the removal mechanisms are not yet fully elucidated. In this study, the occurrence and characteristics of MPs in raw domestic laundry wastewater were investigated. The coagulation process was combined with ultrafiltration (UF) membrane filtration to enhance MP removal. The results showed that the concentrations of MPs in laundry wastewater ranged from 9000 to 11,000 particles/L, with fibrous particles constituting the majority (42.6%) and polyester accounting for 68.2% of detected MPs. Using aluminium chloride and ferric chloride as coagulants, maximum removal efficiencies of 91.7 and 98.3% were achieved, respectively. Mechanistic analysis revealed that charge neutralization played a dominant role during coagulation. Fourier transform infrared spectroscopy further demonstrated the formation of new functional groups, substituted benzene rings, and the presence of Fe-O and Al-O bonds, indicating the interaction between MPs and coagulants. Furthermore, the UF membrane was used to remove fibrous MPs and MPs with low densities. These MPs had not been removed with pre-coagulation. The removal efficiency of these MPs reached 96 ± 2%, reducing their concentration to only 60 particles/L in the UF permeate. These findings highlight the synergistic potential of coagulation and UF membrane filtration for effective MP removal and provide a valuable reference for advancing wastewater treatment technologies targeting MP pollution.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11857315PMC
http://dx.doi.org/10.3390/membranes15020047DOI Listing

Publication Analysis

Top Keywords

laundry wastewater
16
mps
10
coagulation membrane
8
concentrations mps
8
membrane filtration
8
removal
6
wastewater
6
coagulation
5
removal microplastics
4
laundry
4

Similar Publications

Microplastic (MP) pollution has recently emerged as a critical global environmental issue. Laundry wastewater is a significant contributor to MP pollution, containing high concentrations of MPs. Although coagulation has recently been widely applied to remove MPs from such wastewater, its efficiency remains poor, and the removal mechanisms are not yet fully elucidated.

View Article and Find Full Text PDF

A novel approach for rapid quantification and length distribution of microfibers released during domestic laundry.

J Hazard Mater

February 2025

College of Fashion and Design, Donghua University, Shanghai 200051, China; Key Laboratory of Clothing Design & Technology (Donghua University), Ministry of Education, Shanghai 200051, China. Electronic address:

Textile abrasion releases microfiber pollutants, a significant environmental concern, primarily from domestic laundry. A method to directly quantify microfibers in water and calculate their length distribution is lacking. This study aimed to develop a rapid method for quantifying microfibers and to derive a density function of their length distribution.

View Article and Find Full Text PDF

Domestic laundry wastewater is a major contributor to microfiber emissions in the aquatic environment. Among several mitigation measures, the use of external filters to capture microfibers from wastewater is one of the most efficient and commercially viable methods. This study attempted to develop an eco-friendly filtration medium to filter microfibers in laundry wastewater using luffa cylindrica fibers.

View Article and Find Full Text PDF

The increase in maritime traffic has led to substantial greywater discharges into the marine environment. Greywater, originating from sinks, showers, kitchen, and laundry facilities, contains a wide array of chemical contaminants influenced by on-board activities, ship size, and management practices. The lack of comprehensive regulations for greywater management, along with limited research on its chemical composition, highlights the need to characterize these waste streams.

View Article and Find Full Text PDF
Article Synopsis
  • This study explores the use of micro-inter-electrode distances in electrocoagulation to enhance treatment and energy efficiency for low-conductivity laundry wastewater.
  • The research analyzed how different interelectrode distances, current densities, and anode materials impacted the removal rates of pollutants like paracetamol and total organic carbon.
  • Findings show that while micro-distances reduced energy consumption significantly, they also resulted in increased sludge production, highlighting a trade-off in using different electrode materials for optimal performance.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!