Recently, the demand for esthetic restorations has grown dramatically and extended into the pediatric population. The prefabricated zirconia crowns (PZCs) and custom-made zirconia crowns (CZCs) are new esthetic options in pediatric dentistry. However, they are still inadequately tested for use in children. Aim: To determine the fracture resistance and failure mode of the PZC in comparison to the CZC. In this in-vitro study, thirty cobalt-chromium dies were fabricated by scanning the negative replica of a prefabricated lower first permanent molar zirconia crown. CZCs were designed and milled using two different zirconia brands: Ceramill Zolid-FX (FX) and the Highly-Translucent (HT) zirconia. Dies were randomly assigned to receive either a PZC or a CZC (n = 10 in each group). All crowns were cemented on their respective dies using glass ionomer cement. Following artificial aging, all specimens were loaded to failure. Fracture mode analysis was performed. One-way ANOVA and Bonferroni post-hoc test were used for multiple comparisons across the groups. The significant level was set at ≤ 0.05. HT zirconia had a significantly higher fracture load compared to other groups ( < 0.05). The mean fracture resistance values were: (3087 ± 385) N for HT zirconia, (2633 ± 300) N for PZCs, and (2483 ± 381) N for FX, with no statistically significant difference in fracture strengths between PZCs and FX. HT zirconia crowns showed the highest fracture resistance amongst all groups. The fracture loads of tested crowns exceeded the maximum posterior biteforce. When placed in permanent molars, PZC are expected to perform well under masticatory forces in children.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11854477 | PMC |
http://dx.doi.org/10.3390/dj13020064 | DOI Listing |
Evid Based Dent
March 2025
Edinburgh Dental Institute Paediatric Department 39x Lauriston Building, Edinburgh, UK.
A Commentary On: Fehrenbach J, de Soares J L S, do Nascimento Foly J C S, Miotti L L, Münchow E A Mechanical performance of endocrown restorations in anterior teeth: A systematic review and network meta-analysis. Dent Mater 2025; https://doi.org/10.
View Article and Find Full Text PDFACS Appl Mater Interfaces
March 2025
National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, Sichuan, China.
Structural defects and biological inertness significantly impair the integration of titanium alloy implants and bone tissues. In spinal internal fixation, the issue of pedicle screw loosening or fracture caused by poor integration urgently needs solving. In this study, we utilized 3D printing technology to custom fabricate a structurally optimized porous pedicle screw with the aim of enhancing bone regeneration and integration at the defect site, thereby enhancing the biological fixation of the implant .
View Article and Find Full Text PDFObesity (Silver Spring)
March 2025
Section on Gerontology and Geriatric Medicine, Department of Internal Medicine, Wake Forest University School of Medicine, Winston-Salem, North Carolina, USA.
Despite adverse metabolic and functional consequences of obesity (BMI ≥30 kg/m), clinical recommendations for weight loss (WL) in older adults (65+ years) with obesity remain controversial. Reluctance stems partly from epidemiologic data demonstrating musculoskeletal tissue loss with WL and increased risk of disability and osteoporotic fracture. Randomized controlled trials in older adults complement and extend knowledge in this area showing: (1) lifestyle-based WL interventions often yield clinically meaningful (~8%-10%) WL in older adults; (2) lean mass loss is significant, although fat mass loss is preferential and physical performance is often improved, particularly when combined with aerobic and resistance training (RT); (3) bone loss is also significant, with some evidence that RT can attenuate WL-associated bone loss; and (4) fat mass regain after intervention cessation is common, yet physical performance gains appear to be maintained.
View Article and Find Full Text PDFNat Commun
March 2025
School of Materials and Chemistry, Anhui Provincial Engineering Center for High-Performance Biobased Nylons, Anhui Engineering Research Center for Highly Functional Fiber Products for Automobiles, Anhui Agricultural University, Hefei, Anhui Province, 230036, China.
Lightweight, nanoporous aerogel fibers are crucial for personal thermal management and specialized heat protection. However, wet-spinning methods, exemplified by aramid aerogels, inevitably form a dense outer layer, significantly reducing the volume fraction of efficient thermal barrier nanovoids and limiting the development of ultimate thermal resistance in fibers. Herein, we develop a microfluidic spinning method to prepare gradient all-nanostructure aramid aerogel fibers (GAFs).
View Article and Find Full Text PDFJ Pharm Bioallied Sci
December 2024
Department of Oral and Maxillofacial Surgery, Government Dental College and Hospital, Cuddalore, Tamil Nadu, India.
Objective: The primary rationale of the study is to assess the biomechanical aspects of Champy's, monoplanar, biplanar, and 3D strut plating systems using an model in the management of the angle of mandible fracture.
Methods: Thirty-two hemi-sectioned mandibles ( = 32) were obtained from adult goats and divided into four groups ( = 8) for different plating techniques: monoplanar, biplanar, Champy's, and three-dimensional curved angle strut plating. A customized biomechanical test machine simulated masticatory loads by applying compressive forces.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!