Clavicle refractures after hardware removal: are there risk factors? A retrospective cohort study.

Eur J Trauma Emerg Surg

Harald-Tscherne Laboratory for Orthopaedic and Trauma Research, University Hospital Zurich, University of Zurich, Ramistr. 100, 8091, Zurich, Switzerland.

Published: February 2025

Purpose: Removal of symptomatic hardware after fracture fixation is common, especially in patients with clavicle fracture. Yet, refracture after hardware removal is a relatively common complication in those patients. The aim of this study was to identify risk factors for clavicle refractures that could be influenced by the surgical treatment provided.

Methods: All patients from a level one trauma center from 2017 to 2022 were screened for eligibility. Inclusion criteria included hardware removal after plate osteosynthesis of the clavicle, age ≥ 18 years, and signed informed consent. Groups were stratified according to occurrence of refracture: no-refracture (NR) vs. refracture (R). Nearest-neighbor matching in a ratio of 5:1 was performed. Parameter investigated included baseline demographics, fracture characteristics and surgical treatment details. A subgroup analysis of only clavicle shaft fractures was performed.

Results: Sixty patients were included with 50 patients in Group NR and 10 in Group R. Baseline characteristics were comparable between the groups. A subgroup analysis on shaft fractures revealed that a significantly larger working length (number of empty screw holes adjacent to the fracture site) in Group NR (1.94 ± 0.85) compared to the refracture group (1.20 ± 0.92) (p = 0.042). Logistic regression yielded an inverse correlation with the number of empty screw holes to the fracture site and the occurrence of refractures (OR 0.369, 95% CI 0.132-0.873; p = 0.035). Time in situ, lag screw application, plate positioning and the total amount of screws did not affect either of the groups.

Conclusion: An increased working length in patients with clavicle shaft fractures might be a protective measure for occurrence of refractures after hardware removal.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11845419PMC
http://dx.doi.org/10.1007/s00068-025-02794-xDOI Listing

Publication Analysis

Top Keywords

hardware removal
16
shaft fractures
12
clavicle refractures
8
refractures hardware
8
patients clavicle
8
surgical treatment
8
subgroup analysis
8
clavicle shaft
8
working length
8
number empty
8

Similar Publications

Purpose: Current knowledge of complication rates after volar plating of distal radius fractures mainly relies on studies of low to moderate numbers and various implants. This study sought to find the incidence of complications leading to reoperation in a sample of distal radius fractures treated with one specific volar locking plate (VLP).

Methods: We retrospectively evaluated 1,597 distal radius fractures in 1,564 patients operated with a VLP from January 2011 to December 2017 for complications leading to a reoperation.

View Article and Find Full Text PDF

Purpose: Total knee arthroplasty (TKA) in patients who underwent previous knee surgeries can be a challenging procedure both technically and for the complication rate. Conversion TKA is affected by a higher risk of infection compared to primary TKA. The aims of this meta-analysis are i) to compare the infectious risk among patients undergoing TKA after a prior hardware implantation, evaluating removal vs maintenance of the hardware, and ii) within the removal group, to compare staged vs concurrent procedure.

View Article and Find Full Text PDF

Purpose: Investigate intra- and post-operative complications and revisions following distal femoral and/or high tibial derotational osteotomies to correct rotational malalignments of the lower limb in patients with anterior knee pain (AKP) and/or patellofemoral instability (PFI).

Methods: A literature search was conducted on PubMed, EMBASE and Web of Science (until 30 September 2023), including studies reporting complications, reinterventions and revisions following knee derotational osteotomies. Incidence rates were collected for each level of derotational osteotomy (distal femur, high tibia or double-level).

View Article and Find Full Text PDF

Esophageal perforation is a rare but serious complication that can occur post-cervical spine surgery. This case report presents the clinical course, diagnostic challenges and management strategies of a patient who had a late-diagnosis esophageal perforation after anterior cervical spine surgery (ACSS). A woman in her 50s underwent ACSS for cervical spondylosis.

View Article and Find Full Text PDF

Leveraging real-time eye tracking, foveated rendering optimizes hardware efficiency and enhances visual quality virtual reality (VR). This approach leverages eye-tracking techniques to determine where the user is looking, allowing the system to render high-resolution graphics only in the foveal region-the small area of the retina where visual acuity is highest, while the peripheral view is rendered at lower resolution. However, modern deep learning-based gaze-tracking solutions often exhibit a long-tail distribution of tracking errors, which can degrade user experience and reduce the benefits of foveated rendering by causing misalignment and decreased visual quality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!