: Maintaining sufficient ankle joint range of motion (ROM) contributes to efficient movement in sports and daily activities. Static stretching (SS), while effective, demands significant time, highlighting the need for alternative, time-efficient approaches to improve ROM. Therefore, this study aimed to evaluate the effectiveness of combined intervention (CI) using neuromuscular electrical stimulation (NMES) and elastic tape versus SS. : This randomized crossover trial was conducted in healthy university students. They underwent both interventions with a 1-week washout period. The CI entailed the application of elastic tape to the plantar surface of the foot coupled with NMES targeting the posterior lower leg muscles for 1 min. SS was administered for 5 min using a tilt table. Outcome measures included the dorsiflexion angle (DFA), finger-floor distance (FFD), straight leg raise (SLR) angle, plantar flexor strength (PFS), and knee flexor strength (KFS), assessed pre- and post-intervention. DFA was analyzed using equivalence testing with a predefined margin. : Both interventions yielded significant improvements in DFA, FFD, and SLR. The combination of NMES and elastic tape demonstrated equivalence to 5 min of SS in enhancing DFA. Neither intervention resulted in a significant reduction in PFS or KFS. : The CI of NMES and elastic tape effectively and safely improves flexibility in a short time. Its time efficiency makes it a promising alternative to SS, especially for brief warm-ups or limited rehabilitation time. Further research should explore its long-term effects and broader applicability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11843824PMC
http://dx.doi.org/10.3390/jfmk10010058DOI Listing

Publication Analysis

Top Keywords

elastic tape
16
nmes elastic
12
neuromuscular electrical
8
electrical stimulation
8
range motion
8
static stretching
8
flexor strength
8
elastic
5
combined neuromuscular
4
stimulation elastic
4

Similar Publications

: Maintaining sufficient ankle joint range of motion (ROM) contributes to efficient movement in sports and daily activities. Static stretching (SS), while effective, demands significant time, highlighting the need for alternative, time-efficient approaches to improve ROM. Therefore, this study aimed to evaluate the effectiveness of combined intervention (CI) using neuromuscular electrical stimulation (NMES) and elastic tape versus SS.

View Article and Find Full Text PDF

Purpose: To evaluate the safety and efficacy of the magnetic levator prosthesis (MLP) relative to active control with KT Tape, an elastic therapeutic tape used clinically to mechanically open the lids, and to a sham MLP worn in-office only.

Methods: This was a double-masked, randomized crossover single-center trial of patients with severe unilateral or bilateral paralytic blepharoptosis defined as occlusion of the visual axis without frontalis recruitment. Patients were allocated to MLP or tape first and then crossed over after 2 weeks of use and a 2-week washout.

View Article and Find Full Text PDF

Purpose: This study aims to compare the biomechanical performance of elastic and static suture-based cerclage systems to traditional screw constructs in the setting of modeled glenoid bony augmentation.

Methods: Biomechanical testing was conducted on polyurethane cellular foam blocks modeling a 20 % glenoid defect repaired with a coracoid graft. Constructs consisted of an elastic suture-based cerclage, static suture-based cerclage, and a two-screw construct.

View Article and Find Full Text PDF

Improving the Structural Efficiency of Punched-Metal-Material-Based Composites.

Polymers (Basel)

December 2024

Faculty of Civil and Mechanical Engineering, Aeronautics, Space Engineering and Transport Institute, Riga Technical University, LV-1011 Riga, Latvia.

This study investigates the potential of reusing punched-steel waste, a significant component of solid inorganic waste, in composite materials for construction applications. Driven by the growing global demand for raw materials (which is projected to quadruple by 2050) and the need for sustainable waste management practices, this research explores the creation of a composite material (PPLK) incorporating punched-steel tape (LPM-4 grade) embedded in a polypropylene matrix. Experimental testing of PPLK specimens (310 × 90 × 6.

View Article and Find Full Text PDF

Laboratory Investigation on Dynamic Complex Modulus of FRPU Composite.

Materials (Basel)

December 2024

FlexAndRobust Systems Ltd., 24 Warszawska Str., 31-155 Cracow, Poland.

Civil engineering structures are subject to both static and dynamic loadings. This applies especially to buildings in seismic areas as well as bridges, viaducts, and road and railway structures loaded with road or rail traffic. One of the solutions used to repair and strengthen such structures in the event of emergency damage are fibre-reinforced polyurethanes (FRPUs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!