Introduction: To evaluate the accuracy, reliability, and usability of Bend Ease, a novel smartphone-based digital health technology (DHT), which objectively self-measures spinal range of motion (SRoM) and remotely assesses morning stiffness.
Methods: This phase 1 study involved healthy volunteers (HV) and patients with axial spondyloarthritis (axSpA). Participants used Bend Ease by placing a phone against their chest during a forward-flexion bend, and the application collected and processed accelerometry data to measure bend angle in both clinical and at-home settings. Bend Ease measurements were compared to the video-based method (gold standard) and functional ability questionnaires.
Results: The study included 30 HV and 30 patients with axSpA. Bend Ease accurately measured forward-flexion bend angles, demonstrating strong correlation (r = 0.74) and concordance (ρ = 0.71) with measurement by video. Impaired bending for patients with axSpA relative to HV was most pronounced upon waking (65.3° versus 88.3°, P < 0.001), with increasing bend angle improvements observed for patients with axSpA at later time points (71.0° and 75.8° at 30 min and 1 h after waking, respectively). Waking bend angle correlated with self-reported morning stiffness and functional ability scores. A minimum clinically important difference in bend angle of 14 degrees was established for patients with axSpA, providing a benchmark for improvement. Bend Ease demonstrated robust test-retest reliability, and participants reported high usability.
Conclusions: Bend Ease is an accurate, reliable, and user-friendly tool for assessing SRoM. As the first DHT to objectively evaluate morning stiffness upon waking, Bend Ease provides valuable assessments of spinal mobility when it is most impaired.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s40744-025-00746-w | DOI Listing |
Rheumatol Ther
February 2025
Division of Clinical Immunology and Rheumatology, The University of Alabama at Birmingham, Birmingham, AL, USA.
Introduction: To evaluate the accuracy, reliability, and usability of Bend Ease, a novel smartphone-based digital health technology (DHT), which objectively self-measures spinal range of motion (SRoM) and remotely assesses morning stiffness.
Methods: This phase 1 study involved healthy volunteers (HV) and patients with axial spondyloarthritis (axSpA). Participants used Bend Ease by placing a phone against their chest during a forward-flexion bend, and the application collected and processed accelerometry data to measure bend angle in both clinical and at-home settings.
Chem Sci
August 2024
School of Chemistry, Chair of Organic Chemistry, Trinity College Dublin, The University of Dublin, Trinity Biomedical Sciences Institute 152-160 Pearse Street Dublin D02R590 Ireland
We imagine molecules to be perfect, but rigidified units can be designed to bend from their ideal shape, discarding their symmetric elements as they progress through vibrations and larger, more permanent distortions. The shape of molecules is either simulated or measured by crystallography and strongly affects chemical properties but, beyond an image or tabulation of atom-to-atom distances, little is often discussed of the accessed conformation. We have simplified the process of shape quantification across multiple molecular types with a new web-accessible program - SCSD - through which a molecular subunit possessing near-symmetry can be dissected into symmetry coordinates with ease.
View Article and Find Full Text PDFJMIR Cancer
February 2024
Department of Nano and Chemical Engineering, University of California, San Diego, CA, United States.
Background: Frequent sensor-assisted monitoring of changes in swallowing function may help improve detection of radiation-associated dysphagia before it becomes permanent. While our group has prototyped an epidermal strain/surface electromyography sensor that can detect minute changes in swallowing muscle movement, it is unknown whether patients with head and neck cancer would be willing to wear such a device at home after radiation for several months.
Objective: We iteratively assessed patients' design preferences and perceived barriers to long-term use of the prototype sensor.
Behav Res Methods
September 2024
University of Notre Dame, South Bend, IN, USA.
Conditional process models, including moderated mediation models and mediated moderation models, are widely used in behavioral science research. However, few studies have examined approaches to conduct statistical power analysis for such models and there is also a lack of software packages that provide such power analysis functionalities. In this paper, we introduce new simulation-based methods for power analysis of conditional process models with a focus on moderated mediation models.
View Article and Find Full Text PDFJ Synchrotron Radiat
March 2024
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, People's Republic of China.
As a representative of the fourth-generation light sources, the High Energy Photon Source (HEPS) in Beijing, China, utilizes a multi-bend achromat lattice to obtain an approximately 100 times emittance reduction compared with third-generation light sources. New technologies bring new challenges to operate the storage ring. In order to meet the beam commissioning requirements of HEPS, a new framework for the development of high-level applications (HLAs) has been created.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!