Objectives: Valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) has gained popularity as a less invasive alternative to a redo surgical aortic valve replacement (redo-SAVR); which one is the preferred technique in these cases, however, remains a topic of debate, as the available data refer to retrospective studies with few patients or limited follow-up. The present metanalysis aimed to compare the short-term and long-term outcomes of the two techniques in the setting of a failed surgical bioprosthesis.

Methods: PubMed, MEDLINE, and Embase were searched on 10 November 2023 yielding 355 results (PROSPERO ID: CRD42023490612), of which 27 were suitable for meta-analysis. The primary outcomes were short-term and long-term all-causes and cardiovascular mortality. Logarithmic risk ratio (Log RR) and mean difference were used for categorical and continuous data, respectively.

Results: Both redo-SAVR and ViV-TAVI exhibited similar procedural and short-term mortality. However, ViV-TAVI demonstrated lower 1-year mortality [RR: 0.74, 95% confidence interval (CI) (0.57-0.96), P = 0.02], acute kidney injury (RR: 0.47, P < 0.001), bleeding (RR: 0.44, P < 0.001), stroke (RR: 0.70, P < 0.05), and new pacemaker implantation (RR: 0.69, P < 0.05). Conversely, redo-SAVR demonstrated more favorable mean postoperative aortic valve gradients [mean difference 2.59, 95% CI (0.86-4.31), P < 0.01].

Conclusion: Short-term mortality was similar between the groups, but ViV-TAVI showed better survival at 1 year as well as reduced rates of acute kidney injury, bleeding, stroke, and pacemaker implantation. However, redo-SAVR leads to a better hemodynamic profile. Even if collected data come from retrospective studies, the present results could help to guide the choice of the best approach case-by-case according to the patient's clinical profile.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11841718PMC
http://dx.doi.org/10.2459/JCM.0000000000001702DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
transcatheter aortic
8
valve implantation
8
short-term long-term
8
implantation surgery
4
surgery failed
4
failed bioprosthesis
4
bioprosthesis meta-analysis
4
meta-analysis 20 000
4
20 000 patients
4

Similar Publications

Aortic valve stenosis (AVS) is a progressive disease, wherein males more often develop valve calcification relative to females that develop valve fibrosis. Valvular interstitial cells (VICs) aberrantly activate to myofibroblasts during AVS, driving the fibrotic valve phenotype in females. Myofibroblasts further differentiate into osteoblast-like cells and produce calcium nanoparticles, driving valve calcification in males.

View Article and Find Full Text PDF

Successful Percutaneous Extraction of a WATCHMAN FLX Device From the Left Ventricular Outflow Tract.

JACC Case Rep

January 2025

Division of Cardiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA. Electronic address:

Background: Although rare, embolization of left atrial appendage occlusion (LAAO) devices carries a significant morbidity and mortality burden.

Case Summary: An asymptomatic 77-year-old woman with inability to tolerate anticoagulation due to gastrointestinal bleeding presented for 45-day transesophageal echocardiography following LAAO with a Watchman device, which demonstrated incidental device migration to the left ventricular outflow tract (LVOT). Percutaneous extraction was performed using a novel technique with rat tooth/alligator forceps to successfully retrieve the Watchman from the LVOT using a transaortic approach.

View Article and Find Full Text PDF

Background: Acute Stanford type A aortic dissection is a severe emergency condition that, if left untreated, is associated with a high mortality rate. The extent of surgical repair may impact the outcomes of these patients.

Method: Patients operated for acute type A aortic dissection from a multicentre European registry were included.

View Article and Find Full Text PDF

Deep Learning-Based Contrast Boosting in Low-Contrast Media Pre-TAVR CT Imaging.

Can Assoc Radiol J

March 2025

Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

This study investigates the impact of deep learning-based contrast boosting (DL-CB) on image quality and measurement reliability in low-contrast media (low-CM) CT for pre-transcatheter aortic valve replacement (TAVR) assessment. This retrospective study included TAVR candidates with renal dysfunction who underwent low-CM (30-mL: 15-mL bolus of contrast followed by 50-mL of 30% iomeprol solution) pre-TAVR CT between April and December 2023, along with matched standard-CM controls (n = 68). Low-CM images were reconstructed as conventional, 50-keV, and DL-CB images.

View Article and Find Full Text PDF

Background: The development of aortic valve regurgitation (AR) negatively affects the survival of patients with continuous-flow left ventricular assist device (LVAD) support. Although several risk factors have been identified, little is known about the effect of preoperative aortic root and valve morphology on the development of de novo AR after LVAD implantation.

Methods: Between April 2018 and September 2023, 87 patients underwent durable LVAD implantation at our department.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!