Background: HIV displays exceptionally high virus diversity that can impact detection by diagnostic assays, which rely on sequence conservation.
Methods: We tested the m-PIMA HIV-1/2 Detect point-of-care (POC) assay (Abbott Rapid Diagnostics) against a diverse HIV panel of 340 serum/plasma specimens and diluted cultured virus isolates for which viral load (VL) and classified sequences were known, including HIV-1 groups M, N, O, P, Circulating Recombinant Forms (CRF), and Unique Recombinant Forms (URF), and HIV-2. An in silico inclusivity analysis of 53,503 HIV-1 and 68 HIV-2 sequences from NCBI was performed to predict performance of m-PIMA HIV-1/2 Detect against a broader range of circulating strains.
Results: m-PIMA HIV-1/2 Detect detected HIV in 329/340 (96.8 %) tested samples. The mean VL was 3.80 (2.09-6.14) log copies/mL. Among samples with HIV VL >4000 copies/mL (3.60 log copies/mL; m-PIMA HIV-1/2 Detect design sensitivity), 181/181 (100 %) were detected. Among samples with VL between 3.0 and 3.6 log copies/mL, m-PIMA HIV-1/2 Detect detected 93/96 (96.9 %), and 55/63 (87.3 %) samples with VL below 3.0 log copies/mL were detected. At least one member from each subtype/CRF and all URFs were detected. In silico analysis identified 2/53,503 (0.0037 %) HIV-1 (both group O) and 1/68 (1.47 %) HIV-2 (subtype F) sequences with target region mutations that decreased identity below a 90 % threshold.
Conclusions: The m-PIMA HIV-1/2 Detect assay detected each of the major circulating HIV strains, including rare divergent strains. In silico analysis predicted that m-PIMA HIV-1/2 Detect would detect the majority of HIV-1 and HIV-2 strains indicating that this assay can detect the full range of HIV viral diversity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcv.2025.105771 | DOI Listing |
J Clin Virol
February 2025
Abbott Diagnostics, Abbott Park, IL, USA. Electronic address:
Background: HIV displays exceptionally high virus diversity that can impact detection by diagnostic assays, which rely on sequence conservation.
Methods: We tested the m-PIMA HIV-1/2 Detect point-of-care (POC) assay (Abbott Rapid Diagnostics) against a diverse HIV panel of 340 serum/plasma specimens and diluted cultured virus isolates for which viral load (VL) and classified sequences were known, including HIV-1 groups M, N, O, P, Circulating Recombinant Forms (CRF), and Unique Recombinant Forms (URF), and HIV-2. An in silico inclusivity analysis of 53,503 HIV-1 and 68 HIV-2 sequences from NCBI was performed to predict performance of m-PIMA HIV-1/2 Detect against a broader range of circulating strains.
Pan Afr Med J
December 2022
Institute for Health Research, Epidemiological Surveillance and Training, Dakar, Senegal.
Introduction: early infant diagnosis (EID) is crucial in the prevention of mother to child transmission (PMTCT) of human immunodeficiency virus (HIV) and is an essential component for the elimination of HIV. EID can be strengthened in resource-limited countries by the introduction and the roll out of real-time polymerase chain reaction (PCR) technologies via point-of-care (POC) devices which improves treatment in remote areas and reduces turnaround time for clinicians and patients to receive results and linkage to care. The objective of this study was to evaluate the performance of Xpert® HIV-1 Qual Assay (Cepheid) and m-PIMA™ HIV 1/2 Detect (ABBOTT) for EID of HIV-1 and HIV-2.
View Article and Find Full Text PDFJ Acquir Immune Defic Syndr
October 2022
Centre for the AIDS Programme of Research in South Africa (CAPRISA), University of KwaZulu-Natal, Durban, South Africa.
Background: We aimed to evaluate the analytic performance of 3 rapid HIV viral load assays: the novel Xpert HIV-1 VL XC (Xpert XC), Xpert HIV-1 VL (Xpert VL), and m-PIMA HIV-1/2 VL (m-PIMA).
Setting: Two South African clinics.
Methods: We conducted a prospective diagnostic accuracy study.
Cochrane Database Syst Rev
March 2022
UCL Centre for Medical Imaging, Division of Medicine, Faculty of Medical Sciences, University College London, London, UK.
Background: Viral load (VL) testing in people living with HIV (PLHIV) helps to monitor antiretroviral therapy (ART). VL is still largely tested using central laboratory-based platforms, which have long test turnaround times and involve sophisticated equipment. VL tests with point-of-care (POC) platforms capable of being used near the patient are potentially easy to use, give quick results, are cost-effective, and could replace central or reference VL testing platforms.
View Article and Find Full Text PDFCochrane Database Syst Rev
August 2021
UCL Centre for Medical Imaging, Division of Medicine, Faculty of Medical Sciences, University College London, London, UK.
Background: The standard method of diagnosing HIV in infants and children less than 18 months is with a nucleic acid amplification test reverse transcriptase polymerase chain reaction test (NAT RT-PCR) detecting viral ribonucleic acid (RNA). Laboratory testing using the RT-PCR platform for HIV infection is limited by poor access, logistical support, and delays in relaying test results and initiating therapy in low-resource settings. The use of rapid diagnostic tests at or near the point-of-care (POC) can increase access to early diagnosis of HIV infection in infants and children less than 18 months of age and timely initiation of antiretroviral therapy (ART).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!