Background And Objective: Bimatoprost implant 10 µg (Durysta) is an intracameral biodegradable implant that releases bimatoprost to lower intraocular pressure (IOP). The purpose of this study was to prospectively collect effectiveness and safety data after administration of the implant in patients with open-angle glaucoma or ocular hypertension.

Methods: This phase IV, multicenter, prospective, observational, open-label, 18-month study (ARGOS) enrolled adult patients with open-angle glaucoma or ocular hypertension who were scheduled to receive the bimatoprost implant in one or both eyes. Data collected included IOP, use of topical IOP-lowering medications, treatment-emergent adverse events, and central corneal endothelial cell density. The primary endpoint was the proportion of primary (first-treated) eyes that received no additional (new) IOP-lowering treatment per standard medical care through month 6 after the implant administration.

Results: A total of 217 patients (341 eyes) were enrolled, and 132 patients (60.8%) and 203 eyes (59.5%) completed the study. Most patients were on topical IOP-lowering medication before receiving the implant. After implant administration, the proportion of primary eyes that had received no additional treatment was 88.6% (95% confidence interval 86.6-90.6) at month 6 (primary endpoint) and remained high throughout the follow-up: 83.7% (95% confidence interval 80.2-87.3) at month 12 and 77.7% (95% confidence interval 73.4-82.1) at month 18. Intraocular pressure was reduced after implant administration, with mean changes in IOP from baseline at follow-up visits ranging from - 1.0 to - 2.0 mm Hg. The mean number of topical IOP-lowering medications used was also reduced, from 1.8 at baseline to 0.9 at month 12 and 1.0 at month 18. Increased IOP and dry eye were the most common ocular treatment-emergent adverse events. The mean percentage change in central corneal endothelial cell density from baseline at month 18 (central reading center evaluation) was - 3.47%. In qualitative interviews, most patients (84%, 21/25) reported overall satisfaction with their treatment outcomes.

Conclusions: The bimatoprost implant helped control IOP and decrease topical medication use. Throughout the 18 months after implant administration, an estimated 77.7% of eyes required no new added medication for IOP management. Patient-reported outcomes were favorable, and the safety profile of the implant was acceptable.

Clinical Trial Registration: ClinicalTrials.gov identifier NCT04647214, registered 23 November, 2020.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11891102PMC
http://dx.doi.org/10.1007/s40265-025-02157-1DOI Listing

Publication Analysis

Top Keywords

implant
12
patients open-angle
12
open-angle glaucoma
12
glaucoma ocular
12
bimatoprost implant
12
topical iop-lowering
12
implant administration
12
95% confidence
12
confidence interval
12
18-month study
8

Similar Publications

Lithium Bond-Mediated Molecular Cascade Hydrogel for Injury-Free and Repositionable Adhesive Bioelectronic Interfaces.

Adv Mater

March 2025

Key Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education, School of energy and power engineering, Dalian University of Technology, Dalian, 116024, P. R. China.

Flexible bioelectronic interfaces with adhesive properties are essential for advancing modern medicine and human-machine interactions. However, achieving both stable adhesion and non-damaging detachment remains a significant challenge. In this study, a lithium bond-mediated molecular cascade hydrogel (LMCH) for bioelectronic interfaces is designed, which facilitates robust adhesion at the tissue level and permits atraumatic detachment for repositioning as required.

View Article and Find Full Text PDF

Flexible Patterned Fuel Cell Patches Stimulate Nerve and Myocardium Restoration.

Adv Mater

March 2025

College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, 310027, China.

The distribution of electrical potentials and current in exogenous electrostimulation has significant impacts on its effectiveness in promoting tissue repair. However, there is still a lack of a flexible, implantable power source capable of generating customizable patterned electric fields for in situ electrostimulation(electrical stimulation). Herein, this study reports a fuel cell patch (FCP) that can provide in situ electrostimulation and a hypoxic microenvironment to promote tissue repair synergistically.

View Article and Find Full Text PDF

MXenes and MXene-based composites for biomedical applications.

J Mater Chem B

March 2025

Clinical Translational Research Center of Aggregation-Induced Emission, School of Medicine, The Second Affiliated Hospital, School of Science and Engineering, Shenzhen Institute of Aggregate Science and Technology, The Chinese University of Hong Kong, Shenzhen (CUHK-Shenzhen), Guangdong 518172, P. R. China.

MXenes, a novel class of two-dimensional materials, have recently emerged as promising candidates for biomedical applications due to their specific structural features and exceptional physicochemical and biological properties. These materials, characterized by unique structural features and superior conductivity, have applications in tissue engineering, cancer detection and therapy, sensing, imaging, drug delivery, wound treatment, antimicrobial therapy, and medical implantation. Additionally, MXene-based composites, incorporating polymers, metals, carbon nanomaterials, and metal oxides, offer enhanced electroactive and mechanical properties, making them highly suitable for engineering electroactive organs such as the heart, skeletal muscle, and nerves.

View Article and Find Full Text PDF

Infective endocarditis (IE) is a common complication in patients who inject drugs. We present the case of a 36-year-old woman with IE affecting both the aortic and tricuspid valves, along with a cardiac implantable electronic device infection, 11 weeks after combined aortic valve replacement, tricuspid valve replacement, and pacemaker implantation. The patient declined the medically indicated cardiac surgery due to her recent taxing surgical and rehabilitation experiences.

View Article and Find Full Text PDF

Background: This analysis assesses the effectiveness and tolerability profile of vericiguat in patients with heart failure with reduced ejection fraction (HFrEF) and implantable cardioverter-defibrillator, with an emphasis on the emergence of ventricular arrhythmias.

Methods: Retrospective analysis of patients with HFrEF and implantable cardioverter-defibrillator who started treatment with vericiguat in daily clinical practice in a tertiary university hospital in Spain.

Results: The study population comprised 14 patients treated since January 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!