Small-sided games (SSGs) refer to game formats where there are variations in the pitch size, the number of players, and rules as compared to official soccer matches. The purpose of this study was to assess the relationship between GPS-derived external loads and the SSGs' area per player (ApP) in elite youth soccer players to identify whether the ApP influenced GPS-derived external load measures to estimate external load variables from SSGs with different densities (i.e., ApP100: the ApP <150 m•player; ApP200: the ApP ranged from 151 to 250; ApP300: the ApP > 251 m•player). A cumulative count of 978 individual observations was undertaken, encompassing 15 diverse SSG configurations. The results showed moderate and large correlations between the ApP and external load measures for both U19 and U16 soccer players. The ApP300 induced higher locomotor activities than the ApP100 and the ApP200. However, the ApP100 showed higher mechanical (accelerations and decelerations) values compared to ApP200 and ApP300 conditions for both age groups. It was found that an ApP of less than 150 m•player in SSGs did not stimulate enough high-speed distance relative (HSDR), very high-speed distance relative (VHSDR) and sprint distance relative (SDR) compared to official matches in youth soccer players. However, the same ApP overestimated mechanical variables such as total high accelerations and decelerations relative to time (THACCR and THDECR, respectively). The findings of this study have the potential to facilitate the effective management of training loads tailored to specific fitness components of players.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11812169 | PMC |
http://dx.doi.org/10.5114/jhk/189421 | DOI Listing |
Zhong Nan Da Xue Xue Bao Yi Xue Ban
October 2024
Xiangya Stomatological Hospital and Xiangya School of Stomatology, Central South University; Hunan Engineering Research Center for Digital Intelligence and Personalized Medicine; Hunan 3D Printing Engineering Research Center of Oral Care, Changsha 410008.
Objectives: Maxillary transverse deficiency is a common malocclusion frequently observed in orthodontic clinics. Miniscrew-assisted rapid palatal expansion (MARPE) not only produces greater skeletal expansion but also offers advantages such as simple miniscrew implantation without flap elevation, enhanced patient comfort, and an expanded age range and indications for palatal expansion. However, the fixed connection between the expander and the miniscrews makes the expander difficult to remove, significantly hindering its clinical application.
View Article and Find Full Text PDFInt J Sports Physiol Perform
March 2025
Department of Movement, Human and Health Sciences, University of Rome "Foro Italico,"Rome, Italy.
Purpose: To quantify the relationship between load models during official games of the novel 3 × 3 basketball sport.
Methods: Forty-one adult male players were monitored across three 3 × 3 basketball official tournaments. Players wore Firstbeat Sports microsensors to quantify external (Movement Load) and internal physiological (summated-heart-rate-zones [SHRZ]) loads.
Psychol Res
March 2025
School of Education, Guangzhou University, Guangzhou, 510006, People's Republic of China.
Cognitive offloading refers to the use of external tools to assist in memory processes.This study investigates the effects of item difficulty and value on cognitive offloading during a word-pair learning task, comparing children and young adults in a context where both cues coexist. In Experiment 1, we examined the impact of difficulty and value cues on cognitive offloading using a 2 (difficulty: easy vs.
View Article and Find Full Text PDFWearable Technol
February 2025
Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands.
State-of-the-art controllers for active back exosuits rely on body kinematics and state machines. These controllers do not continuously target the lumbosacral compression forces or adapt to unknown external loads. The use of additional contact or load detection could make such controllers more adaptive; however, it can be impractical for daily use.
View Article and Find Full Text PDFFront Bioeng Biotechnol
February 2025
Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University and Guangdong Provincial Clinical Research Center of Oral Diseases, Guangzhou, China.
Purpose: This study aims to investigate the stress distribution in bone tissue, implant, abutment, screw, and bridge restoration when the mesial implant is placed axially and the distal implant is inserted at varying angles in the posterior maxillary region with free-end partial dentition defects, using three-dimensional finite element analysis.
Materials And Methods: Cone-beam computed-tomography were utilized to create 3D reconstruction models of the maxilla. Stereolithography data of dental implants and accessories were used to design a three-unit full zirconia bridge for the maxillary model.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!