This study examined the influence of the effective embedment depth of undercut anchors and the diameter of their heads on the formation of the so-called cone failure angle α. Cone failure formation during simulated anchor pull-out tests was analyzed numerically using the Finite Element Method (FEM) with the ABAQUS software and the XFEM algorithm. The analysis was conducted for three sizes of undercut anchor heads and four embedment depths. The numerical analysis results were compared with field test results obtained during pull-out tests of anchors installed in a rock medium (sandstone). Good agreement was observed between the numerical and field test results. The results of the numerical study are highly consistent with those obtained during the field survey. Moreover, they align closely with findings from previous numerical studies conducted by members of the research team, as presented in earlier publications. For the assumed simulation and field test conditions (sedimentary rocks, gray sandstone), no clear correlation was found between the embedment depth or the anchor head diameter and the value of the cone failure angle in the initial phase of the failure zone development. This result contrasts with certain findings reported in the literature. Many existing studies on anchor bolts focus on material properties or load-bearing capacity, but lack an in-depth analysis of how anchor depth influences the geometry of the failure cone. This research addresses that gap, providing valuable insights with practical implications for design codes and safety evaluations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11819717PMC
http://dx.doi.org/10.3390/ma18030686DOI Listing

Publication Analysis

Top Keywords

cone failure
12
field test
12
anchor depth
8
failure cone
8
embedment depth
8
failure angle
8
pull-out tests
8
anchor
6
failure
6
cone
5

Similar Publications

To reveal the evolution law of the mechanical failure of the root-soil composite and identify the main control factors and their coupling and mutual feeding relationship, this paper takes the most common naturally growing plants in Yan 'an area as the research object and studies the evolution process of the mechanical deformation and failure of the root-soil composite by applying the methods of in-situ pull-out test, indoor direct shear test of the root-soil composite, numerical simulation, and theoretical analysis. The mechanical characteristics of root-soil interaction were analyzed, and the mechanism of root-soil fixation was explained. The results show that: (1) the root-soil composite's mechanical deformation and failure characteristics have obvious regularity and stages and are affected by plant growth state, root morphology, soil physical and mechanical properties, and other factors.

View Article and Find Full Text PDF

Background: The retromolar canal (RMC) is an extension of the mandibular canal located in the distal region of the mandibular third molar. Accurately detecting the RMC using conventional two-dimensional images is challenging, potentially leading to anesthetic failure and sensory disorders. This study aims to explore the clinical application of a radiomic model based on panoramic radiographs in detecting the RMC.

View Article and Find Full Text PDF

Background: The purpose of this study is to assess the short- and mid-term radiographic outcomes of a ream-then-broach metaphyseal cone design for revision total knee arthroplasty (rTKA).

Methods: A retrospective, multicenter analysis of rTKA patients utilizing femoral and/or tibial metaphyseal cone placement from January 2017 to July 2022 was performed. Assessment of radiolucency was performed utilizing a novel "cones score" for radiolucency for tibial and femoral cones.

View Article and Find Full Text PDF

This study examined the influence of the effective embedment depth of undercut anchors and the diameter of their heads on the formation of the so-called cone failure angle α. Cone failure formation during simulated anchor pull-out tests was analyzed numerically using the Finite Element Method (FEM) with the ABAQUS software and the XFEM algorithm. The analysis was conducted for three sizes of undercut anchor heads and four embedment depths.

View Article and Find Full Text PDF

New subperiosteal dental implants were designed to offer new options to edentulous patients with severe bone resorption for whom endosseous dental implants are not advisable. In our study, we aimed to design and manufacture subperiosteal dental implants with a minimum volume to facilitate surgical maneuvers and metal coverage by mucosa while ensuring maximal long-term implant strength and functionality. With cone-beam CT-scan data obtained from an edentulous patient, a maxilla and mandible recreation were created, and subperiosteal implants were designed and analyzed with FEA (250 MPa infinite-life limit stress).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!