A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Acetabular Home Run Screw Guidance for Transiliac Fixation in Cup Revision Arthroplasty. | LitMetric

The growing incidence of acetabular revisions has highlighted the importance of achieving reliable fixation to the remaining bone. Proximal transiliac fixation (TIF) of pelvic implants is becoming an increasingly common approach for managing extensive bone defects. This study seeks to provide guidance on TIF implantation by analyzing the optimal screw placement in partial pelvic replacements for acetabular defects. : Between 2014 and 2024, a cohort of 96 consecutive patients (65 females and 31 males) who underwent customized partial pelvic replacement (PPR) with transiliac fixation (TIF) were examined. The angle and entry point of the ideal TIF were determined using preoperative three-dimensional planning and compared with potential influencing factors. : All PPRs were successfully implanted, with an average TIF length of 77 mm. The mean anteroposterior angle for TIF was 18° medially and 27° dorsally. : Analysis of the entry point showed concentration around the second radius and between the eleven o'clock and one o'clock positions. The AP angle is notably affected by gender and height. Considering the precision of human judgment, a recommendation for TIF placement would be 20° medial and 30° dorsal deviation, with the entry point around the twelve o'clock position and the second ring from the center of the cup.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11818629PMC
http://dx.doi.org/10.3390/jcm14030922DOI Listing

Publication Analysis

Top Keywords

transiliac fixation
12
entry point
12
fixation tif
8
partial pelvic
8
tif
7
acetabular screw
4
screw guidance
4
guidance transiliac
4
fixation
4
fixation cup
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!