Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
: Features of pericoronary adipose tissue (PCAT) from coronary computed tomography angiography (CCTA) are associated with inflammation and cardiovascular risk. As PCAT is vascularly connected with coronary vasculature, the presence of iodine is a potential confounding factor on PCAT HU and textures that has not been adequately investigated. We aim to use dynamic cardiac CT perfusion (CCTP) to understand the perfusion of PCAT and determine its effects on PCAT assessment. : From CCTP, we analyzed HU dynamics of territory-specific PCAT, the myocardium, and other adipose depots in patients with coronary artery disease. HU, blood flow, and radiomics were assessed over time. Changes from peak aorta time, P, chosen to model the acquisition time of CCTA, were obtained. : HU in PCAT increased more than in other adipose depots. Blood flow in PCAT was ~23% of that in the contiguous myocardium. A two-second offset [before, after] P resulted in [4 ± 1.1 HU, 3 ± 1.5 HU] differences in PCAT, giving a 7 HU swing. Due to changes in HU, the apparent PCAT volume reduced by ~15% from the first scan (P) to P using a conventional fat window. Comparing radiomic features over time, 78% of features changed >10% relative to P. Distal and proximal to a significant stenosis, we found less enhancement and longer time-to-peak distally in PCAT. : CCTP elucidates blood flow in PCAT and enables the analysis of PCAT features over time. PCAT assessments (HU, apparent volume, and radiomics) are sensitive to acquisition timing and obstructive stenosis, which may confound the interpretation of PCAT in CCTA images. Data normalization may be in order.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11818118 | PMC |
http://dx.doi.org/10.3390/jcm14030769 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!