Risk of Dental Implant Failure with Obesity. | LitMetric

Purpose: To measure the association between dental implant failure and obesity.

Materials And Methods: A retrospective cohort study was performed to investigate the association between implant failure and obesity. The time to implant failure and other covariates of interest were studied, including sex, history of periodontal disease, and smoking. A consecutive series of implant patients were studied from January 1, 2000, through September 30, 2021, in the Department of Dental Specialties at the Mayo Clinic in Rochester, Minnesota. Obesity was measured through the patient's body mass index (BMI), which was calculated from their height and weight closest to the date of implant placement (within 12 months). They were then categorized as 'not overweight or obese' (BMI ≤ 24.9), 'overweight' (BMI 25.0 to 29.9), or 'obese' (BMI ≥ 30). Kaplan-Meier models were compared using a log rank test to assess the associations of demographic and systemic conditions with implant failure. Survival curves and hazard ratios (HRs) were calculated at the implant level separately from BMI, sex, and smoking.

Results: The sample included 6,241 patients who received 16,921 implants. The mean age was 54.43 years (SD: 17.04), and 42.7% of the patients were male. A total of 5,847 implants were placed in 2,161 patients categorized as 'obese,' with 327 implants failing in 171 patients. BMI status was not found to be a risk for implant failure in the population or setting studied (HR: 0.97; 95% CI 0.82-1.15; P value = 0.44). Current smokers (P < .0001) and males (P = .015) were significantly associated with implant failure.

Conclusions: Obesity was not shown to be associated with an increased risk of implant failure.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.10783DOI Listing

Publication Analysis

Top Keywords

implant failure
28
implant
11
dental implant
8
failure obesity
8
risk implant
8
failure
7
bmi
6
patients
5
risk dental
4
obesity
4

Similar Publications

Aims: Inter-atrial shunt device therapy has shown mixed results in clinical trials, with clinical 'non-responders' typically showing features of more advanced heart failure. We aimed to analyse the haemodynamic and clinical response of a novel left atrial to coronary sinus (LA-CS) shunt device in patients with higher natriuretic peptide (NP) levels, a marker of disease severity.

Methods And Results: An analysis population (n = 95) of patients from the ALT-FLOW early feasibility study with left ventricular ejection fraction >40% and 1-year follow up was analysed.

View Article and Find Full Text PDF

Background And Objective: Natural language processing (NLP) is a subfield of artificial intelligence that enables computers to process human language. As most human interactions today involve the internet and electronic devices, NLP tools quickly become indispensable to modern life. The use of NLP tools in medical practice and research is growing fast.

View Article and Find Full Text PDF

The prognostic value of defibrillators in cardiac resynchronization therapy (CRT) for primary prevention remains debatable. Predicting ventricular arrhythmias (VAs) before implantation is useful for deciding whether to add a defibrillator to a CRT device. This study aimed to determine the risk factors for VA events after CRT device implantation and to construct a scoring model.

View Article and Find Full Text PDF

Introduction: Despite the success of two-stage exchange total knee arthroplasties(TKAs), a subset of patients become reinfected and may be considered for a repeat two-stage exchange TKAs. A small, prior study from our institution demonstrated a 50% re-revision rate in such a cohort. The purpose of the present study was to evaluate a contemporary and larger cohort of repeat two-stage exchange TKAs with an emphasis on implant survivorship, risk factors, and clinical outcomes.

View Article and Find Full Text PDF

Objectives: This article aims to present a proof-of-concept surgical technique for immediate reconstruction of zygoma anatomy following implant failure and complications, illustrating the related clinical steps in a cadaver specimen. Zygomatic implants represent a paradigm shift, addressing challenges posed by severe maxillary bone atrophy and partial or complete maxillectomy, not suitable for conventional dental implant placement. Despite documented high survival rates, intra- and postoperative complications can occur and lead to implant failure, resulting in severe defects extended up to entire height of zygomatic bone pyramid.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!