Background: Cup anteversion after primary total hip arthroplasty (THA) with monobloc dual mobility cups (DMC) is difficult to measure on anterior-posterior (AP) pelvic radiographs because of the implant radiopacity and cup design which do not allow for an accurate visualization of the radiographic projection of the cup equatorial rim and the femoral head. This study aims to radiographically investigate on the reliability and accuracy of different measurement methods for cup anteversion in monobloc DMC THA, by comparing a novel titanium cup with conventional cup designs.

Methods: 97 THAs with a monobloc 3D-printed titanium DMC were radiographically assessed for cup radiographic anteversion (RA) one month postoperatively. RA were measured by three blinded observers through Lewinnek, Woo-Morrey methods and an open access mathematical software (GeoGebra), used as reference method. Intra- and interobserver reliability of RA measurements were evaluated for each method using intraclass correlation coefficient (ICC). Accuracy was assessed comparing Lewinnek and Woo-Morrey methods with GeoGebra. Moreover, further 98 THAs with conventional different brand DMC were radiographically assessed as control group by using the same methods.

Results: ICC for intra- and interobserver reliability for RA measurements with GeoGebra, Lewinnek and Woo-Morrey methods were 0.975-0.980, 0.978 - 0.965, and 0.979 - 0.958, respectively, for the titanium DMC group. Lewinnek resulted more accurate for RA than Woo-Morrey, differing by + 0.4° (p = 0.06) and + 4.4° (p < 0.001) from GeoGebra, respectively. ICC for intra- and interobserver reliability for GeoGebra, Lewinnek and Woo-Morrey methods were 0.848 - 0.756, 0.843 - 0.801, and 0.965 - 0.958, respectively, for the control DMC group. Lewinnek and Woo-Morrey methods differed by -2.3° and + 5.1° from GeoGebra, respectively (p < 0.001).

Conclusions: RA measurements are more consistent, repeatable and accurate with a titanium DMC than standard DMC, due to the minor radiopacity of the former cup which enable RA measurements on AP radiographs. Conversely, RA measurements of conventional DMC are more consistent but less accurate if performed on cross-table lateral radiographs by Woo-Morrey method than AP radiographs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11806696PMC
http://dx.doi.org/10.1186/s13018-025-05555-zDOI Listing

Publication Analysis

Top Keywords

cup anteversion
12
lewinnek woo-morrey
12
woo-morrey methods
12
cup
9
dual mobility
8
titanium dmc
8
dmc radiographically
8
radiographically assessed
8
intra- interobserver
8
interobserver reliability
8

Similar Publications

Objective: This study aimed to explore whether total hip arthroplasty (THA) aided by full-process robotics was effective in patients undergoing developmental dysplasia of the hip (DDH).

Methods: Totally 112 patients were enrolled and classified into robotic-assisted group (n = 56) and the conventional group (n = 56). In addition, retrospective analysis was used for comparing the difference in therapeutic efficacy.

View Article and Find Full Text PDF

Background: The present study aimed to examine the impact of prior experience of computed tomography-based navigated THA (CTN-THA) on the accuracy of cup placement in robotic arm-assisted total hip arthroplasty via direct anterior approach using the Mako system (Mako-THA).

Methods: We evaluated the first 60 hips that underwent Mako-THA performed by surgeons with and without CTN-THA experience and compared the absolute error of pre-operative and post-operative cup placement using a three-dimensional template between the two groups.

Results: The CTN-user group demonstrated significantly better results in radiographic inclination, y-(sagittal) axis placement, and z-(vertical) axis placement than the non-CTN-user group (CTN-user group: 1.

View Article and Find Full Text PDF

Objective: In recent years, the paradigm of surgical approaches for total hip arthroplasty (THA) has evolved, with portal-assisted techniques emerging as a promising avenue for increasing precision and minimizing invasiveness. The purpose of this study was to compare early experience with the Microport anterior percutaneously assisted total hip arthroplasty (MAP) system, with the established AMIS direct anterior approach (DAA).

Material And Methods: A retrospective chart analysis was performed on 200 consecutive patients who underwent DAA or MAP at our institution in 2022.

View Article and Find Full Text PDF

Purpose: Accurate cup placement is challenging in total hip arthroplasty (THA) for dysplastic hip osteoarthritis (DHOA) because of the complex morphology of the acetabulum. Studies have reported good accuracy for total hip arthroplasty (THA) using computed tomography-based navigation (CTN); however, in recent years, portable navigation (PN) has become more widely applied because of its low cost and ease of use. This study aimed to compare the accuracy of portable navigation with that of CT-based navigation.

View Article and Find Full Text PDF

Background: Patients often report leg-length discrepancy (LLD) after total hip arthroplasty (THA). The factors behind self-reported LLD (sLLD) are unclear. Robot-assisted THA (RA-THA) offers improved precision, but its effect on sLLD has not been well studied.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!