Aims: This study aimed to investigate whether the use of CT-based navigation enhances: 1) the accuracy of cup placement; and 2) the achievement rate of required range of motion (ROM). Additionally, we investigated the impact of using a large femoral head and dual-mobility liner on the achievement rates.
Methods: This retrospective study analyzed 60 manual and 51 CT-based navigated primary total hip arthroplasties performed at a single facility. Postoperative CT scans and CT-based simulation software were employed to measure the cup orientation and to simulate the ROM. We compared the absolute errors for radiological inclination (RI) and radiological anteversion (RA) between the two groups. We also examined whether the simulated ROM met the required ROM criteria, defined as flexion > 110°, internal rotation > 30°, extension > 30°, and external rotation > 30°. Furthermore, we performed simulations with 36 mm femoral head and dual-mobility liner.
Results: The absolute errors of RI and RA from the preoperative plan were significantly smaller in the CT-based navigation group (3.7° (SD 3.5°) vs 5.1° (SD 3.5°); p = 0.022, and 3.9° (SD 3.5°) vs 6.8° (SD 5.0°); p = 0.001, respectively). The proportion of cases achieving the required ROM in all directions was significantly higher in the CT-based navigation group (42% vs 63%; p = 0.036). The achievement rates of the required ROM were significantly higher with the use of a 36 mm ball or dual-mobility liner compared to the use of a 32 mm ball (65% vs 51%; p = 0.040 and 77% vs 51%; p ≤ 0.001, respectively).
Conclusion: CT-based navigation enhanced required ROM achievement rates by > 20%, regardless of the ball diameter. The improved accuracy of cup placement through CT-based navigation likely contributed to the enhancement. Furthermore, the use of large femoral heads and dual-mobility liners also improved the required ROM achievement rates. In cases with a high risk of dislocation, use of these devices is preferred.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11805587 | PMC |
http://dx.doi.org/10.1302/2633-1462.62.BJO-2024-0084.R1 | DOI Listing |
BMC Musculoskelet Disord
March 2025
Department of Orthopedic Surgery, Showa University Fujigaoka Hospital, 1-30 Fujigaoka Aoba-ku, Yokohama, 227-8501, Japan.
Background: Transtrochanteric rotational osteotomy (TRO) for osteonecrosis of the femoral head (ONFH) is considered technically demanding, with varying results among institutions. This is due to the complex soft tissue exposure and determination of the osteotomy line. We report a case in which the osteotomy line was assessed using the Stryker OrthoMap three-dimensional (3D) computed tomography (CT)-based navigation system and determined as preoperatively planned.
View Article and Find Full Text PDFEur J Orthop Surg Traumatol
March 2025
Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya-shi, Japan.
Purpose: Accurate cup placement is challenging in total hip arthroplasty (THA) for dysplastic hip osteoarthritis (DHOA) because of the complex morphology of the acetabulum. Studies have reported good accuracy for total hip arthroplasty (THA) using computed tomography-based navigation (CTN); however, in recent years, portable navigation (PN) has become more widely applied because of its low cost and ease of use. This study aimed to compare the accuracy of portable navigation with that of CT-based navigation.
View Article and Find Full Text PDFBrain Sci
February 2025
Department of Neurosurgery, University Hospital Marburg, Philipps University Marburg, Baldingerstrasse, 35043 Marburg, Germany.
Pharmacoresistant epilepsy affects approximately one-third of all epilepsy patients, and resective surgery may offer favorable outcomes for carefully selected patients with focal epilepsy. The accurate identification of the epileptogenic zone (EZ) is essential for successful surgery, particularly in cases where non-invasive diagnostics are inconclusive. Invasive diagnostics with stereoelectroencephalography (SEEG) offer a reliable approach to localizing the EZ, especially in MRI-negative cases.
View Article and Find Full Text PDFBone Jt Open
February 2025
Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Aims: This study aimed to investigate whether the use of CT-based navigation enhances: 1) the accuracy of cup placement; and 2) the achievement rate of required range of motion (ROM). Additionally, we investigated the impact of using a large femoral head and dual-mobility liner on the achievement rates.
Methods: This retrospective study analyzed 60 manual and 51 CT-based navigated primary total hip arthroplasties performed at a single facility.
Front Vet Sci
January 2025
Divison of Small Animal Surgery, Department of Clinical Veterinary Medicine, Vetsuisse-Faculty, University of Bern, Bern, Switzerland.
Introduction: Sacroiliac luxation is a common traumatic feline injury, with the small size of the sacral body being a challenge for surgical stabilization. This study compared an innovative computer-guided drilling method with the conventional fluoroscopy-controlled freehand technique. Neuronavigation, using CT-based planning and real-time tracking, was evaluated against the freehand method for accuracy and time efficiency.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!