Extended reality includes both virtual and augmented realities. In virtual reality objects are rendered in an artificial environment where the user can move and interact with a head mounted display. In augmented reality virtual objects are superimposed to real environment enriching it via a head mounted display. In human medicine these technologies have been already used for educational surgical purposes, but remain relatively unknown in veterinary medicine. We report a case of a 1-year-old, female, French bulldog presented for exercise intolerance and dyspnea. Echocardiography showed signs of left ventricular enlargement with reduced fractional shortening and turbulent flow distal to the pulmonary artery bifurcation. Computed tomography revealed a complex vascular network comprising the descending aorta and left pulmonary artery resembling a patent ductus arteriosus. Virtual reality was used for the surgical planning and a left thoracotomy was performed to close the abnormal vessel at the level of the entrance in the left pulmonary artery with augmented reality assistance. No complications were reported during or after the surgery and the dog completely recovered. Echocardiographic findings 3 days, 1 month and 18 months after the surgery demonstrated absence of residual flow and improving ventricular dimensions. To our knowledge this report documents the first use of extended reality for the visualization, planning and execution of the surgical correction of a complex vascular defect in veterinary medicine.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11805765PMC
http://dx.doi.org/10.1007/s11259-025-10668-1DOI Listing

Publication Analysis

Top Keywords

complex vascular
12
pulmonary artery
12
extended reality
8
virtual reality
8
head mounted
8
mounted display
8
augmented reality
8
veterinary medicine
8
left pulmonary
8
reality
6

Similar Publications

Objectives: Although there has been rapid development in the field of three-dimensional morphological analyses of congenital heart disease, with the three-dimensional volume-rendered images providing visualization of the external vascular anatomy, the precise reproduction of "Swiss-cheese" ventricular septum is not well established. We created three-dimensional printed models and computer graphics based on multi-slice computed tomography of patients with complex multiple ventricular septal defects for surgical decision planning of this difficult cardiac defect.

Methods: Seven patients with complex multiple ventricular septal defects were evaluated preoperatively using three-dimensional printed models and computer graphics to plan therapeutic interventions.

View Article and Find Full Text PDF

Digital subtraction angiography (DSA) is the gold standard for assessing cerebrovascular hemodynamics. DSA is predominantly utilized to evaluate the hemodynamic information of various cerebral diseases. However, DSA is relatively invasive and involves radiation exposure and risks of allergic reactions or renal dysfunction related to iodine-based contrast agents.

View Article and Find Full Text PDF

Perioperative bleeding is and remains a major complication during and after surgical interventions, resulting in increased morbidity and mortality. The main causes of a non-primary vascular-related bleeding are congenital or multifactorial pre-existing hemostatic disorders that have not yet been diagnosed, the operating procedure itself and acquired hemostatic abnormalities as a secondary phenomenon, e.g.

View Article and Find Full Text PDF

Purpose: To compare automated and semiautomated methods for the measurement of retinal microvascular biomarkers: the automated retinal vascular morphology (AutoMorph) algorithm and the Singapore "I" Vessel Assessment (SIVA) software.

Methods: Analysis of retinal fundus photographs centered on optic discs from the population-based Montrachet Study of adults aged 75 years and older. Comparison and agreement evaluation with intraclass correlation coefficients (ICCs) between SIVA and AutoMorph measures of the central retinal venular and arteriolar equivalent, arteriolar-venular ratio, and fractal dimension.

View Article and Find Full Text PDF

Continuous Kidney Replacement Therapies: Core Curriculum 2025.

Am J Kidney Dis

March 2025

Division of Nephrology, Department of Medicine, University of Ottawa, Ottawa, Ontario, Canada. Electronic address:

Critically ill patients that require kidney replacement therapy (KRT) are among the most ill and complex patients routinely encountered in the intensive care unit (ICU). Continuous KRT (CKRT) is used across many ICUs as the therapy of choice for hemodynamically unstable patients with kidney failure. Though existing trials have not shown superior survival or kidney recovery with CKRT relative to intermittent KRT, CKRT has largely become the standard of care in developed nations for the treatment of acute kidney injury (AKI) in patients with shock, acute brain injury, acute liver failure, and other forms of critical illness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!