Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Unlabelled: There is currently an exponential increase in the prevalence of childhood obesity thus warranting the demand to appropriately measure and evaluate cardiorespiratory fitness within educational settings. The aims of this study were to (1) compare measured peak oxygen consumption (VOpeak), heart rate peak (HRpeak), and 1-min heart rate recovery (HRRec) responses obtained using a GXTmax and the PACER test; and (2) compare the VOpeak from the GXTmax and PACER test to a PACER prediction equation (ScottEqua).
Methods: This study included 32 (16 boys) children. Despite not having maturational assessments on these children, we limited the subject's age range from 10-11 year old's to decrease the possibility of including additional variability in pubertal status. The participants were classified by body mass index for age and sex percentiles (BMI%) as Healthy-Weight (HW BMI% ≤ 85 percentile) or At-Risk (AR BMI% > 85 percentile). Participants completed the GXTmax and PACER tests while wearing a portable metabolic system to measure VOpeak; and these measures were compared to the estimated VOpeak using the ScottEqua. Group mean differences and correlation analysis were used to compare the testing and predictive procedures.
Results: We found no significant differences between the GXTmax and PACER VOpeak; however, the Scott Equa VOpeak was significantly greater than these measures. HRpeak was significantly greater during the GXTmax; but no significant HRRec were found.
Conclusions: The PACER and GXTmax provide similar VOpeak measures; however, PACER prediction equations should be used with caution in children 10-11 years.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11798550 | PMC |
http://dx.doi.org/10.70252/XTQW5048 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!