Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Hemorheological properties, such as erythrocyte aggregation can be assessed by ultrasonic backscatter coefficient analysis. In this study, a data-acquisition sequence with dual-frequency (dual-f) excitation was proposed to expand the ultrasonic frequency bandwidth with high-frame-rate imaging. The approach was experimentally validated using ex vivo porcine blood measurements and in vivo human imaging. The center frequency of the excitation wave was alternated between 7.8 (f) and 12.5 (f) MHz in the frequency spectral analysis using the reference phantom method. The frequency spectra revealed that the dual-f sequence achieved a bandwidth of 4.5-15 MHz at -20 dB, almost equivalent to those achieved with conventional single-frequency excitation (5.0-15 MHz) with a short-duration wave at 10 MHz (mono-f) in reference media with the sufficient condition of signal-to-noise ratio. The aggregation and disaggregation states of porcine blood suspended in high-molecular-weight dextran were determined by the isotropic diameter and packing factor using the structure factor size estimator. The discrimination performance of the dual-f approach increased, owing to the broadband frequency responses, in contrast with the limited performance of mono-f due to a low signal-to-noise ratio. This approach incorporating dual-f sequence is beneficial for obtaining robustly frequency spectra of hemorheological properties from in vivo scenarios.