Monitoring the CO concentration is crucial for assessing respiratory illnesses in humans and safeguarding the environment. The ongoing difficulty lies in achieving highly sensitive detection while also eliminating the interference caused by humidity. There is an unmet need for portable sensors with both high sensitivity and good moisture resistance to monitor CO in real time. In this study, a novel sensor capable of capturing the piezoelectric signals induced by CO gas is developed. A quartz crystal microbalance (QCM) coated with a mixed- matrix membrane of metal-organic framework (MOF)/polyether block amide (Pebax) is designed as a transducer to detect CO at room temperature. The change in the concentration of CO can be detected by the frequency shift of the QCM sensor. The sensor shows an ultrahigh sensitivity of 371.8 Hz to 1000 ppm of CO because of the abundant polar group and nitrogen Lewis basic groups. Furthermore, the implementation of a self-humidity compensation algorithm significantly enhances the accuracy and reliability of CO concentration monitoring by effectively addressing the issue of humidity interference. Our research underscores the immense potential of MOF/Pebax QCM sensors with self-humidity compensation ability in the field of CO gas monitoring.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acssensors.4c03535 | DOI Listing |
ACS Sens
February 2025
State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China.
Monitoring the CO concentration is crucial for assessing respiratory illnesses in humans and safeguarding the environment. The ongoing difficulty lies in achieving highly sensitive detection while also eliminating the interference caused by humidity. There is an unmet need for portable sensors with both high sensitivity and good moisture resistance to monitor CO in real time.
View Article and Find Full Text PDFNat Commun
August 2024
National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China.
Real-time and accurate biomarker detection is highly desired in point-of-care diagnosis, food freshness monitoring, and hazardous leakage warning. However, achieving such an objective with existing technologies is still challenging. Herein, we demonstrate a wireless inductor-capacitor (LC) chemical sensor based on platinum-doped partially deprotonated-polypyrrole (Pt-PPy and PPy) for real-time and accurate ammonia (NH) detection.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!