A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The value of ultrasound viscosity imaging in preoperative differential diagnosis between malignant and benign breast lesions: Preliminary clinical applications. | LitMetric

Objective: To investigate the value of ultrasound viscosity imaging in preoperative differential diagnosis between malignant and benign breast lesions.

Methods: This prospective study was approved by our institutional review board and informed consents were signed by all patients. Patients diagnosed with focal solid breast lesions who plan to undergo surgical or ultrasound guided core needle biopsy were included. A Mindray Resona R9 Elite diagnostic ultrasound system equipped with a linear array transducer (L15-3 MHz) was used. First BMUS was used to identify the lesions, afterwards, ultrasound viscosity imaging and shear wave elastography measurements were performed for each lesion. Viscosity (Pa*s) coefficient and shear-wave speed (m/s) of each breast lesion were measured. Taking the final histopathological results as the gold standard, the optimal cut-off value of viscosity and elastography values in differential diagnosis between malignant and benign breast lesions were evaluated. Diagnostic performance was assessed by using the area under the receiver operating characteristic curve (ROC).

Results: From July 2023 to March 2024, 159 consecutive patients with a total of 184 solid breast lesions were included. Among which 74 (40.2%) malignant lesions and 110 (59.8%) benign ones were diagnosed according to the final histopathological results. The mean maximal viscosity coefficient (7.56±3.63 Pa*s) of malignant lesions was significantly higher than that of benign ones (4.52±2.33 Pa*s), whereas the mean maximal SWE value (6.53±1.87 m/s) of malignant lesions was also obviously higher than that of benign ones (4.80±1.62 m/s) (P < 0.05). The cut-off value for diagnosis of malignant breast tumors was 5.39 Pa*s for viscosity, with 75.68% sensitivity, 68.18% specificity and 0.763 AUROC (P < 0.05). When combined viscosity with SWE values, the sensitivity and specificity was 75.68% and 75.45%, with an-area under the receiver operating characteristic curve (AUC) 0.787.

Conclusions: The value of viscosity measurement may provide additional value for preoperative non-invasive differential diagnosis between malignant and benign breast lesions.

Download full-text PDF

Source
http://dx.doi.org/10.3233/CH-242405DOI Listing

Publication Analysis

Top Keywords

breast lesions
16
ultrasound viscosity
12
viscosity imaging
12
differential diagnosis
12
diagnosis malignant
12
malignant benign
12
benign breast
12
malignant lesions
12
imaging preoperative
8
preoperative differential
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!