Objective: To evaluate outcomes after flexible ureteroscopy (F-URS) for renal stone(s) using a flexible and navigable suction ureteral access sheath (FANS-UAS) comparing Thulium fiber (TFL) vs pulsed Thulium:Yttrium aluminum garnet (p-Thulium:YAG) laser.

Methods: Data from adults who had F-URS in 5 centers were prospectively collected (April 2023-January 2024). All patients had a preoperative and within 30days CT scan. Stone-free: grade A: zero fragments; grade B: single fragment ≤2mm; grade C: single fragment 2.1-4mm; grade D: single/multiple fragments >4 mm. One-to-one propensity score-matching for age, gender, prestenting, stone volume, stone location, and Hounsfield units was performed. Within 6months after surgery, an intravenous urography or CT urography scan was performed in all patients.

Results: Of 179 included patients, TFL was employed in 115 patients. After matching, 64 patients from each group with comparable baseline characteristics were included. Median lasing time was significantly longer in the TFL group (15.5 [10,23] minutes vs 13 [10,15] minutes, P=.02), while total surgical time did not differ. There was no case of blood transfusion and sepsis. Overall stone-free rate (SFR) was significantly different between the groups with a higher proportion of patients in p-Thu:YAG laser group undergoing reintervention for residual fragments (17.2% vs 3.1%). There was no case of new-onset hydronephrosis, ureteropelvic junction/ureteral stenosis, impaired urinary drainage, or altered pelvicalyceal anatomy at a median follow-up of 13weeks.

Conclusion: F-URS using FANS-UAS showed negligible serious adverse events and good SFR using both lasers. p-Thu:YAG laser showed shorter lasing time, marginal better grade A+B SFR but higher reintervention rate for residual fragments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.urology.2025.01.065DOI Listing

Publication Analysis

Top Keywords

thulium fiber
8
pulsed thuliumyttrium
8
thuliumyttrium aluminum
8
aluminum garnet
8
flexible ureteroscopy
8
flexible navigable
8
navigable suction
8
suction ureteral
8
ureteral access
8
access sheath
8

Similar Publications

Stone ablation using the thulium fiber laser (TFL) at different pulse duration/peak power or laser fiber-to-stone distances requires further research to understand effective and safe settings. In this study we characterized the vapor bubble anatomy and stone crater morphology at various settings and standoff distances. Optical profiles of 1 J short pulse (SP), 1 J long pulse (LP), 3 J SP, and 2.

View Article and Find Full Text PDF

Reply Letter to the Editor on "Evaluating Noise Emissions of Endourological Lasers: A Comparative Analysis of Ho:YAG, Tm:YAG, and Thulium Fiber Laser Systems".

Urology

February 2025

GRC n°20, Groupe de Recherche Clinique sur la Lithiase Urinaire, Hôpital Tenon, Sorbonne Université, 75020, Paris, France; Service d'Urologie, Assistance-Publique Hôpitaux de Paris, Hôpital Tenon, Sorbonne Université, 4 rue de la Chine, 75020, Paris, France.

View Article and Find Full Text PDF

Exploring the optimal parameter settings of a thulium fiber laser during soft tissue resection.

Lasers Med Sci

February 2025

Department of Urology, Cancer Precision Diagnosis and Treatment and Translational Medicine Hubei Engineering Research Center, Zhongnan Hospital of Wuhan University, 169 Donghu Road, Wuhan, 430071, China.

There is a lack of clinical consensus on the parameter settings of the pulsed-wave thulium fiber laser for soft tissue resection. The aim of this study was to explore the optimal parameter settings of the pulsed-wave thulium fiber laser for soft tissue resection, with a view to providing a reference for future clinical applications. Two different thulium fiber lasers, prototype thulium fiber lasers and Urolase, were used to explore the optimal parameters of thulium fiber laser for soft tissue cutting by evaluating the depth of tissue vaporization and depth of thermal damage in an isolated pig kidney model, and then the optimal parameters of in vitro screening were statistically validated by operation time, coagulation time, intraoperative hemorrhage, smoke level, and depth of thermal damage in an in vivo model using rabbit kidney.

View Article and Find Full Text PDF

Background: The direct in-scope suction (DISS) involves a two-way adaptor mounted on a scope to aspirate and irrigate the pelvicalyceal system during flexible ureteroscopy. While integrated suction single-use scopes manage small dust particles effectively, they cannot remove particles >250 µm and are limited by single use.

Objectives: To evaluate perioperative outcomes of the GLITZ system, a lightweight suction accessory for flexible ureteroscopes, facilitating laser lithotripsy with integrated aspiration.

View Article and Find Full Text PDF

Prior laser studies have demonstrated that as the temperature of a medium increases, the amount of energy delivered to the target increases. We sought to investigate the role of irrigation fluid temperature on Thulium fiber laser (TFL) urolith ablation. 360 calculi were divided in vitro according to chemical composition: calcium oxalate monohydrate (COM), cystine (CYS), struvite (STR), calcium phosphate (CAP), uric acid (UA), and calcium oxalate dihydrate (COD).

View Article and Find Full Text PDF