Alzheimer's disease (AD) is a severe neurodegenerative disease that requires early diagnosis to manage its progression. Although the simultaneous detection of multiple AD biomarkers is expected to facilitate early assessment of AD risk, the lack of multiplexed sensing platforms for accurately quantifying multiple AD biomarkers remains a challenge. Here, we present a multiplexed digital sensing platform based on bumpy core-shell (BCS) surface-enhanced Raman spectroscopy (SERS) nanoprobes for ultrasensitive, quantitative, and simultaneous detection of Aβ42 and Aβ40 as AD biomarkers, enabling the accurate determination of the Aβ42/Aβ40 ratio. We synthesized BCS SERS nanoprobes with distinct Raman reporters to generate unique, intense, and reproducible SERS signals, offering single-nanoparticle sensitivity and quantification capabilities. These nanoprobes were subsequently employed in SERS-based immunoassays combined with digital SERS analysis for multiplexed quantification. The proposed platform accurately and quantitatively detected Aβ42 and Aβ40 across a range of five orders of magnitude, with a limit of detection of 8.7× 10 g/mL (1.9 × 10 M) for Aβ42 and 1.0 × 10 g/mL (2.3 × 10 M) for Aβ40, surpassing the performance of conventional enzyme-linked immunosorbent assays. Based on the exclusive detection of Aβ42 and Aβ40 using distinct SERS nanoprobes, the proposed sensing platform can also accurately quantify Aβ42 and Aβ40 at clinically relevant levels in both cerebrospinal fluid and blood plasma. Therefore, this sensing platform can be used to accurately and reliably determine the Aβ42/Aβ40 ratio, thus serving as an effective tool for the early diagnosis of AD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2025.117216DOI Listing

Publication Analysis

Top Keywords

sensing platform
16
aβ42 aβ40
16
sers nanoprobes
12
platform accurately
12
multiplexed digital
8
digital sensing
8
alzheimer's disease
8
early diagnosis
8
simultaneous detection
8
multiple biomarkers
8

Similar Publications

Semiautomated Production of Cell-Free Biosensors.

ACS Synth Biol

March 2025

Department of Chemical and Biological Engineering, Northwestern University, Evanston, Illinois 60208, United States.

Cell-free synthetic biology biosensors have potential as effective diagnostic technologies for the detection of chemical compounds, such as toxins and human health biomarkers. They have several advantages over conventional laboratory-based diagnostic approaches, including the ability to be assembled, freeze-dried, distributed, and then used at the point of need. This makes them an attractive platform for cheap and rapid chemical detection across the globe.

View Article and Find Full Text PDF

Vestibular deficits are common and debilitating, and many patients struggle with dynamic balance, even after treatment with standard rehabilitation techniques. The objective of this study was to measure changes in computerized dynamic posturography sensory ratio information after computerized vestibular retraining therapy (CVRT). This prospective, single-group, interventional study enrolled adult participants with stable, unilateral vestibular deficits.

View Article and Find Full Text PDF

Existing technologies for distributed light-field mapping and light pollution monitoring (LPM) rely on either remote satellite imagery or manual light surveying with single-point sensors such as SQMs (sky quality meters). These modalities offer low-resolution data that are not informative for dense light-field mapping, pollutant identification, or sustainable policy implementation. In this work, we propose LightViz-an interactive software interface to survey, simulate, and visualize light pollution maps in real time.

View Article and Find Full Text PDF

Surface Grafting of Graphene Flakes with Fluorescent Dyes: A Tailored Functionalization Approach.

Nanomaterials (Basel)

February 2025

NEST, Istituto Nanoscienze-CNR and Scuola Normale Superiore, Piazza San Silvestro 12, 56127 Pisa, Italy.

The controlled functionalization of graphene is critical for tuning and enhancing its properties, thereby expanding its potential applications. Covalent functionalization offers a deeper tuning of the geometric and electronic structure of graphene compared to non-covalent methods; however, the existing techniques involve side reactions and spatially uncontrolled functionalization, pushing research toward more selective and controlled methods. A promising approach is 1,3-dipolar cycloaddition, successfully utilized with carbon nanotubes.

View Article and Find Full Text PDF

With the increasing development of metaverse and human-computer interaction (HMI) technologies, artificial intelligence (AI) applications in virtual reality (VR) environments are receiving significant attention. This study presents a self-sensing facial recognition mask (FRM) utilizing triboelectric nanogenerators (TENG) and machine learning algorithms to enhance user immersion and interaction. Various TENG negative electrode materials are evaluated to improve sensor performance, and the efficacy of a single sensor is confirmed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!