Implantable cardiac monitors (ICMs) are useful in the detection of tachycardias, bradycardias, and atrial fibrillation. Undersensing and oversensing of events occur despite complex algorithms. The devices available have subtle differences, which may account for a difference in recorded characteristics. The electrocardiogram (ECG) characteristics of different monitors may influence their ability to correctly identify the events recorded. The objective is to compare the ECG characteristics of two commercially available implantable loop monitors and the ability to improve diagnostic accuracy. Two cohorts of patients were examined. Cohort 1 consisted of 30 patients with a Reveal LINQ I (Medtronic, Minneapolis, MN, USA) implanted, which was replaced with a BIOMONITOR III (Biotronik, Berlin, Germany) when the former had reached end of life. The new monitor was implanted at the same site in all patients. This provided a unique opportunity to compare ECGs obtained by both devices with no other confounding variable. Cohort 2 consisted of patients who had undergone implantation of either device at the discretion of the physician. This was therefore a retrospective analysis of 106 patients who had been implanted with one of the devices within a 2-year period. In both cohorts, we compared R-wave amplitude, the ability to accurately detect P-waves, and the frequency of undersensing and oversensing of events. In cohort 1, the mean R-wave was 0.35 ± 0.2 mV with the LINQ I as compared to 0.98 ± 0.4 with the BIOMONITOR III ( = .001). A P-wave in sinus rhythm was present in 19 (63%) subjects with the LINQ I implants versus 28 (93%) with the BIOMONITOR III implants ( = .004). Undersensing of events was noted in five (16%) patients with the LINQ I versus five (16%) with the BIOMONITOR III ( > .5). Oversensing was seen in 4 patients (13.33%) with the LINQ I versus 0 with the BIOMONITOR III ( = .012). In cohort 2, the mean R-wave with the BIOMONITOR III was significantly greater than with the LINQ I (0.65 ± 0.37 vs. 0.48 ± 0.38; = .02). A visible P-wave was seen in 33 of 53 patients with the BIOMONITOR III as compared to 16 of 536 patients with the LINQ I monitor ( = .01). The number of patients identified as having under- or oversensing was, however, not significantly different ( = .08) in this cohort. In both patient cohorts, the BIOMONITOR III was noted to have significantly greater R-wave amplitude as compared with the LINQ I. A visible P-wave was also more commonly seen in patients with a BIOMONITOR III. In the paired cohort, but not in the unpaired cohort, the BIOMONITOR III was less likely to oversense R-waves. There was no significant difference in undersensing between the devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11784397PMC
http://dx.doi.org/10.19102/icrm.2025.16013DOI Listing

Publication Analysis

Top Keywords

biomonitor iii
40
undersensing oversensing
12
oversensing events
12
patients
11
biomonitor
10
iii
10
characteristics commercially
8
commercially implantable
8
implantable loop
8
loop monitors
8

Similar Publications

Wood density is a critical control on tree biomass, so poor understanding of its spatial variation can lead to large and systematic errors in forest biomass estimates and carbon maps. The need to understand how and why wood density varies is especially critical in tropical America where forests have exceptional species diversity and spatial turnover in composition. As tree identity and forest composition are challenging to estimate remotely, ground surveys are essential to know the wood density of trees, whether measured directly or inferred from their identity.

View Article and Find Full Text PDF

The global surge in diabetes mellitus (DM) and its associated complications has prompted significant efforts to mitigate this growing public health challenge. Among these complications, diabetic nephropathy (DN) is of particular concern due to its high rates of morbidity and mortality. Extensive research has identified methylglyoxal (MGO) and MGO-derived advanced glycation end products (AGEs) as critical contributors to the pathogenesis of DN.

View Article and Find Full Text PDF

Background: Neuroendocrine neoplasms (NENs) comprise a group of rare tumors originating from neuroendocrine cells, which are present in both endocrine glands and scattered throughout the body. Due to their scarcity and absence of specific markers, diagnosing NENs remains a complex challenge. Therefore, new biomarkers are required, ideally, in easy-to-obtain blood samples.

View Article and Find Full Text PDF

Given the range of threats facing aquatic ecosystems, it is critical we have monitoring tools to quickly and efficiently identify stressors within ecosystems. Metallothionein's (MTs) are a group of proteins widely used as biomarkers of metal exposure, however, their suitability has been questioned due to their influenceable nature and ability to be induced by various stressors. Through our study, we sought to 1.

View Article and Find Full Text PDF

Model-based management of macrophytes in shallow lakes under warming.

J Environ Manage

March 2025

UR EABX, INRAE, 50 Avenue de Verdun, 33612, Cestas-Gazinet, France; Pole R&D ECLA Ecosystèmes Lacustres, France. Electronic address:

Macrophytes are a critical component of freshwater ecosystems, harboring significant biodiversity and providing essential resources and services. However, their habitat faces multifaceted challenges from climate change, local anthropogenic disturbance, and biological invasions. Here, we aim to provide local management suggestions under both current and future higher temperature regimes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!