Background: To investigate the functional results of the AcrySof IQ Vivity (Alcon, Fort Worth, TX) extended depth-of-focus intraocular lens (EDoF-IOL) and explore correlations between the preoperative biometric parameters and the postoperative functional outcomes.
Methods: In a prospective, single-center, non-randomized study, axial length, keratometry, anterior chamber depth, scotopic and photopic pupil diameters, pupil decentration, corneal asphericity, corneal higher-order aberrations (HOAs), coma and spherical aberration were measured preoperatively. The EDoF-IOL was implanted bilaterally. Three months postoperatively, manifest refraction, monocular and binocular uncorrected and corrected visual acuity at 4 m, 66 cm and 40 cm, binocular defocus curve, binocular contrast sensitivity, halometry and Strehl ratio were measured. Visual disturbances and spectacle independence were assessed with McAlinden and IOLSAT questionnaires, respectively. Assuming a minimum Pearson r correlation coefficient between variables of 0.5 with a power of 80% and a P value less than 0.05, a minimum sample size of 29 (58 eyes) cases was required.
Results: Forty-three patients were enrolled. Binocular distance corrected visual acuity was lower than 0.1 logMAR for a defocus between + 1.0 and - 1.5 D. The mean values at 66 cm and 40 cm were - 0.07 ± 0.06 and 0.19 ± 0.13 logMAR, respectively. McAlinden's questionnaire revealed mean scores close to zero for all questions. The IOLSAT questionnaire showed that spectacles were never used for distance and intermediate vision. Regression analysis did not disclose any significant correlation between the preoperatively measured variables and the postoperative outcomes, with a few exceptions: preoperative higher order corneal aberrations were correlated to halometry area (r = 0.2592, P = 0.0006) and the Q value to contrast sensitivity (r = 0.1717, P = 0.00574) under photopic conditions with glare at a spatial frequency of 18 cpd and without glare for all spatial frequencies (P < 0.01); it was also correlated to contrast sensitivity under mesopic conditions without glare at a spatial frequency of 12 cpd (r = 0.2311, P = 0.0011).
Conclusions: In healthy unoperated eyes, the visual outcomes for this EDoF-IOL are independent of most of the patients' preoperative parameters. Attention should be paid to preoperative corneal aberrations and asphericity, which did not lead to visual disturbances, but may be potential sources of halo and reduced contrast sensitivity.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11787752 | PMC |
http://dx.doi.org/10.1186/s40662-024-00424-y | DOI Listing |
J Cataract Refract Surg
March 2025
Ophthalmology Unit, Centro Hospitalar Universitário de Coimbra (CHUC), Unidade Local de Saúde (ULS) de Coimbra, Portugal.
Purpose: To assess the real-life impact of preoperative visual simulations with SimVis Gekko (SVG) on predicting postoperative visual performance in patients undergoing bilateral cataract surgery with trifocal or extended depth of focus (EDOF) intraocular lenses (IOL).
Setting: Centro Hospitalar Universitário de Coimbra, Portugal.
Design: Single-center prospective observational cohort study.
Purpose: To evaluate the clinical and patient-reported outcomes of the toric version of a refractive extended depth of focus intraocular lens (IOL).
Methods: This was a prospective observational study including 26 eyes of 26 patients (age range: 58 to 88 years) who underwent cataract surgery with implantation of the LuxSmart toric IOL (Bausch & Lomb GmbH). Changes in distance, intermediate (80 cm), and near (40 cm) visual acuities, manifest refraction, defocus curve, distance photopic contrast sensitivity (CSV-1000 test), and patient-reported outcomes (Catquest-9SF questionnaire) were evaluated during a 3-month follow-up.
Front Med (Lausanne)
February 2025
Sussex Eye Hospital, University Hospitals Sussex NHS Foundation Trust, Brighton, United Kingdom.
Purpose: Mini-monovision is a vision correction technique that allows for a broader spectrum of spectacle independence while minimizing anisometropia. This systemic review aims to evaluate the clinical outcomes of pseudophakic mini-monovision with three types of intraocular lenses (IOLs): monofocal, enhanced monofocal, and extended depth of focus (EDOF).
Methods: A comprehensive literature search was conducted using PubMed and MEDLINE to identify studies reporting mini-monovision outcomes within the three categories of IOLs up to July 2024.
Indian J Ophthalmol
March 2025
Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India.
Purpose: The purpose is to study the change in the contact of the IOL with the posterior capsule using intraoperative SD-OCT before and after implantation of the CTR post implantation of the IOL in the capsular bag.
Methods: A total of 51 eyes of 51 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of an extended depth of focus intraocular lens by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging.
J Microsc
February 2025
Department of Physics and Technology, UiT The Arctic University of Norway, Norway, Norway.
In the scanning acoustic microscopy (SAM) imaging, it is essential to address the diminished lateral resolution in the out-of-focus region, as image quality correlates with the ultrasound propagation distance either above or below the focal plane. To focus the scanned image, a refocusing technique called synthetic aperture focusing technique (SAFT) is widely used, which improves the resolution by extending the depth of focus manually. In SAM, refocusing the image accurately is challenging without prior defocusing information.