Minimally invasive internal splinting technique for acute closed Achilles tendon rupture.

J Orthop Surg Res

Department of Orthopedics, Jingzhou Hospital Affiliated to Yangtze University, Jingzhou Hubei, 434020, China.

Published: January 2025

Background: Although non-surgical and surgical approaches have been developed to repair acute closed Achilles tendon ruptures, the medical community still lacks a definitive consensus on which approach is superior. This study describes a new minimally invasive internal splinting technique combined with knotless anchors for the treatment of 22 patients with acute closed Achilles tendon rupture.

Methods: A retrospective study was conducted involving 22 patients with acute closed Achilles tendon rupture who were treated with a minimally invasive internal splinting technique at Jingzhou Hospital of Yangtze University between January 2022 to October 2023. The study recorded and compared various metrics, including the Visual analogue scale (VAS), American Orthopedic Foot and Ankle Society (AOFAS), Achilles tendon total rupture score (ATRS), and range of motion (ROM) of the plantar-flexor-extensor foot, both preoperatively and at the final follow-up.

Results: We bridged the intact portion of the Achilles tendon proximal to the rupture site and the calcaneal bone using a Krackow locking loop suture technique and a knotless anchor staple technique. Twenty-two patients were monitored over a period from 10 to 12 months, with an average follow-up duration of (11.6 ± 0.67) months. At the last follow-up, all patients had successfully resumed their sports activities and work without experiencing any complications, such as Achilles tendon rupture, postoperative infection, and peroneal nerve injury. The VAS score postoperatively was recorded at (0.14 ± 0.35), representing a significant reduction from the preoperative score of (4.05 ± 0.58). The AOFAS-AH score improved to (97.41 ± 4.00), a notable increase compared to the preoperative score (52.82 ± 4.43). Similarly, the ATRS score reached (98.23 ± 2.98), also significantly higher than the preoperative score (56.95 ± 4.62). Furthermore, the range of motion (ROM) was measured at (44.27 ± 1.08), significantly surpassing the preoperative value of (26.91 ± 2.09), with all differences being statistically significant (p < 0.05).

Conclusion: The procedure is simple. Two small incisions are placed over the intact proximal Achilles tendon and the calcaneus without surgical invasion of the rupture site, which promotes the natural repair of the ruptured Achilles tendon. The intact proximal Achilles tendon and the calcaneus are securely bridged with high-strength sutures and knotless anchors, reducing complications and promoting healing of the Achilles tendon.

Download full-text PDF

Source
http://dx.doi.org/10.1186/s13018-025-05550-4DOI Listing

Publication Analysis

Top Keywords

achilles tendon
28
acute closed
16
closed achilles
16
minimally invasive
12
invasive internal
12
internal splinting
12
splinting technique
12
tendon rupture
12
preoperative score
12
patients acute
8

Similar Publications

Background: Although non-surgical and surgical approaches have been developed to repair acute closed Achilles tendon ruptures, the medical community still lacks a definitive consensus on which approach is superior. This study describes a new minimally invasive internal splinting technique combined with knotless anchors for the treatment of 22 patients with acute closed Achilles tendon rupture.

Methods: A retrospective study was conducted involving 22 patients with acute closed Achilles tendon rupture who were treated with a minimally invasive internal splinting technique at Jingzhou Hospital of Yangtze University between January 2022 to October 2023.

View Article and Find Full Text PDF

We sought to clarify the interface pressure (IP) and its variation by applying Biflex16, a calibrated bandage, to the lower leg. In Study I, 50 participants applied a bandage to the lower leg of a single subject in two ways: first, with 50% overlap, while the calibration rectangle became a square (Application 1), and then with 50% overlap without intentional stretch (Application 2) which served as a control. In Study II, another 51 participants applied the bandage to their lower leg via Application 1.

View Article and Find Full Text PDF

An Aligned-to-Random PLGA/Col1-PLGA/nHA Bilayer Electrospun Nanofiber Membrane Enhances Tendon-to-Bone Healing in a Murine Model.

Am J Sports Med

January 2025

Department of Orthopaedic Surgery/Sports Medicine Center, Southwest Hospital, Army Medical University, Chongqing, China.

Background: The challenge of achieving effective tendon-to-bone healing remains a significant concern in sports medicine, necessitating further exploration. Biomimetic electrospun nanomaterials present promising avenues for improving this critical healing process.

Purpose: To investigate the biological efficacy of a novel aligned-to-random PLGA/Col1-PLGA/nHA bilayer electrospun nanofiber membrane in facilitating tendon-to-bone healing.

View Article and Find Full Text PDF

Background: We sought to determine the wound complications associated with a straight midline incision overlying the Achilles tendon. Data on sex, age, body mass index (BMI), surgery performed, date of surgery, and wound development were collected.

Methods: We retrospectively collected data on 217 patients with a mean ± SD age of 46.

View Article and Find Full Text PDF

The real rotational capacity of the human joints - the muscular and gravitational torques and the foot as a platform.

Acta Bioeng Biomech

September 2024

Jagiellonian University Medical College, Faculty of Medicine, Department of Bioinformatics and Telemedicine, Kraków, Poland.

The purpose was to answer what is the relationship between torques acting on the human body, how does the triceps calf muscle balance the weight of a tilted body and what is the foot's role in the titling body? Two research models were developed. Model 1 - the one-sided lever system consists of a flat bar with, an axis of rotation, used to determine the weight and torque at a given point on it. Model 2 - the two-sided lever system consists of a flat bar imitating a tilted body counteracted by the Achilles tendon, and a platform imitating a foot.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!