Implantation of a self-expanding valve into a degenerated mechanically expanding aortic valve.

Kardiol Pol

3rd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, Silesian Center for Heart Diseases, Zabrze, Poland.

Published: January 2025

Download full-text PDF

Source
http://dx.doi.org/10.33963/v.phj.104481DOI Listing

Publication Analysis

Top Keywords

implantation self-expanding
4
self-expanding valve
4
valve degenerated
4
degenerated mechanically
4
mechanically expanding
4
expanding aortic
4
aortic valve
4
valve
2
implantation
1
degenerated
1

Similar Publications

Re-sheathing failure with Navitor during transcatheter aortic valve implantation: a case report.

Eur Heart J Case Rep

January 2025

The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.

Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.

Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.

View Article and Find Full Text PDF

The increasing age of patients with end-stage renal disease raises the issue of hostile arterial access for transplantation, with technical difficulties associated with clamping and suturing the iliac artery. Some of these patients - who theoretically represent those who would benefit the most from transplantation in terms of mortality - are contraindicated because of anatomical and medical issues. In this context, a specific endovascular device called EndoPreKiT (Endovascular Preparation for Kidney Transplantation) has been designed, enabling arterial access for transplantation via a mini-invasive procedure.

View Article and Find Full Text PDF

Valve Frame Geometry and Arrhythmia Risk Following Self-Expanding Transcatheter Pulmonary Valve Replacement.

Pediatr Cardiol

January 2025

School of Medicine, Children's Hospital Colorado, The Heart Institute, University of Colorado Denver|Anschutz Medical Campus, 13123 E 16Th Ave, Box 100, Aurora, CO, 80045-2560, USA.

Though major complications during transcutaneous pulmonary valve replacement (TPVR) are rare, clinically-significant ventricular arrythmia (CSVA) has been reported following self-expanding valve placement. We assess whether alterations in valve frame dimensions and geometry within the right ventricular outflow tract (RVOT) post-implantation in patients who underwent TPVR with Harmony TPV25 or Alterra contribute to CSVA risk. A single center review was performed of patients who underwent TPVR with either Harmony TPV25 or Alterra Pre-stent between August 2019 and April 2023.

View Article and Find Full Text PDF

Objective: We present our experience with endovascular Bentall procedure (Endo-Bentall) using a modular valve conduit (Endo-Bentall) in high-risk patients with aortic root pathologies.

Methods: The physician constructed Endo-Bentall device is composed of a self-expanding transcatheter aortic valve (TAVR), aortic endovascular stent graft (TEVAR), and two wire-reinforced fenestrations for coronary artery stenting. The TAVR valve is sutured into an appropriately sized TEVAR graft.

View Article and Find Full Text PDF