Introduction: Limited information exists on next-generation sequencing (NGS) success for lung tumors of 30 mm or less. We aimed to compare NGS success rates across biopsy techniques for these tumors, assess DNA sequencing quality, and verify reliability against surgical resection results.

Methods: We used data from the Initiative for Early Lung Cancer Research on Treatment study, including patients with lung tumors measuring 30 mm or less who had surgery and NGS on biopsies since 2016. We collected data on biopsy type, nodule characteristics, complications, sequencing feasibility, clinical actionable variants, surgery type, and TNM classification. We compared NGS feasibility and quality between biopsy methods and, for those with NGS on surgical samples, compared feasibility, quality, and detection of actionable variants.

Results: Among the 654 participants with lung tumors of 30 mm or less who underwent surgery, 70 had NGS on prior biopsies. The median age was 68.5; 51.4% were male individuals, and 75.7% were smokers. The mean diameter of biopsied nodules was 17.7 mm, with 67.1% fine-needle aspiration, 17.1% computed tomography-guided transthoracic core needle biopsies, and 17.1% endobronchial ultrasound-guided transbronchial needle aspiration. DNA sequencing was feasible in 97.1% of biopsy samples; 2.9% had low tumor cellularity. Coverage depth was achieved in 89.7% of biopsies. RNA sequencing was successful in 66.2% of biopsies, especially in core needle biopsies. Actionable alterations were found in 41.4% of patients. Among the participants, 30% had NGS on surgical samples. RNA sequencing was more feasible on surgical samples (95.2% versus 42.9% for biopsies). NGS on surgical samples matched biopsy results in 90% of patients, with 10% showing additional alterations.

Conclusion: DNA sequencing succeeded in 97.1% of biopsies of nodules 30 mm or less, whereas RNA sequencing feasibility was lower. NGS on biopsy samples is generally reliable but requires careful review.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11773006PMC
http://dx.doi.org/10.1016/j.jtocrr.2024.100777DOI Listing

Publication Analysis

Top Keywords

surgical samples
20
biopsy samples
12
lung tumors
12
dna sequencing
12
ngs surgical
12
rna sequencing
12
ngs
9
next-generation sequencing
8
samples
8
sequencing
8

Similar Publications

Background: The immune heterogeneity of biliary atresia (BA) presents a challenge for development of prognostic biomarkers. This study aimed to identify early immune signatures associated with biliary drainage after Kasai Portoenterostomy (KPE).

Methods: Serum samples, liver slides, and clinical data were obtained from patients enrolled in the NIDDK-supported Childhood Liver Disease Research Network.

View Article and Find Full Text PDF

Purpose: Given the potential role of nasolacrimal duct (NLD) morphometry in the aetiology of primary acquired obstructions, it is imperative that clinicians have access to detailed anatomical information. The aim of this study was to determine normative data on nasolacrimal duct morphometry in the Turkish population sample and to provide guidelines for clinicians.

Methods: The study included retrospectively computed tomography images of a healthy Turkish population sample of 151 individuals, 79 of whom were female and 72 of whom were male.

View Article and Find Full Text PDF

Introduction And Aims: Blood loss is a common side-effect in orthognathic surgery. Deliberated hypotensive anaesthesia can reduce blood loss. The purpose was to evaluate the effect of add-on dexmedetomidine compared with the usual hypotensive drug bolus on blood loss and patient outcomes in orthognathic surgery.

View Article and Find Full Text PDF

Fast is fine, but accuracy is everything: making intraoperative transfusion decisions using point-of-care testing.

Br J Anaesth

February 2025

Transfusion Research Unit, Department of Public Health and Preventative Medicine, Monash University, Melbourne, VIC, Australia; Department of Clinical Haematology, Monash Health, Clayton, VIC, Australia.

Accurate and timely diagnostic information is a vital adjunct to clinical assessment to inform therapeutic decision-making, including decisions to transfuse, or not transfuse, blood components. A prospective cohort study of diagnostic point-of-care (POC) haemoglobin measurements on arterial or central venous samples from adults undergoing major noncardiac surgery compared three widely used devices, HemoCue®, i-STAT™, and the Rad-67™ pulse CO-Oxymeter® finger sensor device, against standard laboratory haemoglobin measurements, but importantly not against a blood gas analyser. The study focused on haemoglobin results below 100 g L to establish the utility of these devices to guide red cell transfusion decisions.

View Article and Find Full Text PDF

Objectives: Chronic Kidney Disease (CKD) has been associated with a prothrombotic state. CKD affects hemostasis through altered platelet function and coagulation factors. Traditional tests provide limited insight into these changes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!