Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.

Case Summary: We describe a 75-year-old woman with Churg-Strauss syndrome and diabetes mellitus who underwent surgical replacement of bioprosthetic aortic and mitral valves 11 years ago. One year ago, she had a transcatheter mitral ViV procedure due to bioprosthetic mitral valve degeneration. The patient was referred to our centre with fatigue and fever, alongside elevated white blood cell count, erythrocyte sedimentation rate, and C-reactive protein. Blood and urine cultures tested positive for . Echocardiographic assessments revealed a paravalvular abscess (13 × 8 mm) in the posterolateral side of the bioprosthetic mitral valve, fistulized into the left ventricle. The patient received treatment with vancomycin, meropenem, and colistin and was a candidate for surgery. Eleven days after the patient's admission, she passed away.

Discussion: This study underscores the novelty of IE complicated with paravalvular abscess following the ViV procedure. In such cases, a multidisciplinary approach and timely surgical interventions are crucial for optimal patient outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11770396PMC
http://dx.doi.org/10.1093/ehjcr/ytaf013DOI Listing

Publication Analysis

Top Keywords

viv procedure
16
bioprosthetic mitral
12
mitral valve
12
infective endocarditis
8
transcatheter mitral
8
paravalvular abscess
8
mitral
6
bioprosthetic
5
procedure
5
complicated infective
4

Similar Publications

Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.

View Article and Find Full Text PDF

Background: Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is associated with improved perioperative safety compared to redo surgical aortic valve replacement (redo-SAVR), but long-term outcomes remain uncertain. We therefore compare long-term outcomes of ViV-TAVR and redo-SAVR.

Methods: The study included 1:1 propensity-matched Medicare beneficiaries with degenerated bioprosthetic valves admitted between 09/29/2011 and 12/30/2020 undergoing either redo-SAVR or ViV-TAVR.

View Article and Find Full Text PDF

Proton magnetic resonance spectroscopy (MRS) offers a non-invasive, repeatable, and reproducible method for in vivo metabolite profiling of the brain and other tissues. However, metabolite fingerprinting by MRS requires high signal-to-noise ratios for accurate metabolite quantification, which has traditionally been limited to large volumes of interest, compromising spatial fidelity. In this study, we introduce a new optimized pipeline that combines LASER MRS acquisition at 11.

View Article and Find Full Text PDF

Severe mitral regurgitation (MR) following surgical repair of the mitral valve poses a significant clinical challenge. Patients who have undergone surgery are typically at high risk for a second operation. This report details the case of a 54-year-old male who underwent aortic valve replacement and mitral valve repair using a 34-ring, 14 years prior.

View Article and Find Full Text PDF

In the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) era, implanting a larger-sized valve during the initial aortic valve replacement is important. For smaller aortic annuli, combining aortic annular and left ventricular outflow tract (LVOT) enlargement is essential. The Y-incision procedure helps achieve implantation of a 2-size larger valve.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!