This study assessed the reliability of Roche Accu-Chek Inform II glucometers in a real-world setting. A retrospective analysis was conducted on 6,695 paired results. Capillary samples were tested using Roche Accu-Chek Inform II glucometers, while venous samples were analyzed using Roche Cobas c503/702 analyzers. Compliance was assessed using modified criteria based on the ISO 15197 guideline and the CLSI EP09-A3 guideline using Passing-Bablok regression analysis, Bland-Altman plots, and Surveillance Error Grid (SEG) analysis. The overall compliance of glucometer results within ±15% or 0.83 mmol/L (15 mg/dL) of the reference method was 81.5%, below the acceptance criterion of 94.6%. SEG analysis showed that 90.3% of the paired results fell within the No-risk zone, with less than 0.001% in the moderate/lower-risk zone. The Emergency Department results indicated 87.8% overall compliance and 92.2% of pairs falling in the No-risk zone. Based on the regression analysis, the glucometer results showed a positive constant bias of nearly 0.33 mmol/L (6 mg/dL). The Bland-Altman plots showed a positive mean difference of 0.43 mmol/L for results ≤5.55 mmol/L (≤100 mg/dL) and a positive mean percentage difference of 3.77% for results >5.55 mmol/L (>100 mg/dL), within the permissible deviation. The compliance values ranged from 76.0% to 90.3% for clinical concentration groups, with the highest compliance found between >16.65-22.20 mmol/L (>300-400 mg/dL). The Accu-Chek Inform II glucometers demonstrated in real-world reliability, with most results falling within acceptable risk categories. However, compliance still needs improvement, so manufacturers should assess opportunities for advancement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/00365513.2025.2456917 | DOI Listing |
Scand J Clin Lab Invest
January 2025
Department of Medical Biochemistry, Health Science University, Istanbul Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.
This study assessed the reliability of Roche Accu-Chek Inform II glucometers in a real-world setting. A retrospective analysis was conducted on 6,695 paired results. Capillary samples were tested using Roche Accu-Chek Inform II glucometers, while venous samples were analyzed using Roche Cobas c503/702 analyzers.
View Article and Find Full Text PDFSensors (Basel)
December 2024
GLUCUBE, 41011 Seville, Spain.
Background: The need for frequent blood glucose (BG) monitoring and the inconveniences associated with self-monitoring of BG (SMBG) have driven the development of non-invasive approaches.
Methods: This prospective study aimed to investigate the accuracy of glucose level calculation using the near-infrared spectroscopy (NIRS) technology system. People with Type 1 diabetes, Type 2 diabetes, prediabetes, and normal glucose metabolism were included.
J Diabetes Sci Technol
September 2024
Science Consulting in Diabetes GmbH, Düsseldorf, Germany.
The last 25 years of CGM have been characterized above all by providing better and more accurate glucose values in real time and analyzing the measured glucose values. Trend arrows are the only way to look into the future, but they are often too imprecise for therapy adjustment. While AID systems provide algorithms to use glucose values for glucose control, this has not been possible with stand-alone CGM systems, which are most used by people with diabetes.
View Article and Find Full Text PDFJ Diabetes Sci Technol
September 2024
Roche Diabetes Care Deutschland GmbH, Mannheim, Germany.
Background: Despite abundant evidence demonstrating the benefits of continuous glucose monitoring (CGM) in diabetes management, a significant proportion of people using this technology still struggle to achieve glycemic targets. To address this challenge, we propose the Accu-Chek SmartGuide Predict app, an innovative CGM digital companion that incorporates a suite of advanced glucose predictive functionalities aiming to inform users earlier about acute glycemic situations.
Methods: The app's functionalities, powered by three machine learning models, include a two-hour glucose forecast, a 30-minute low glucose detection, and a nighttime low glucose prediction for bedtime interventions.
J Diabetes Investig
October 2024
Hung Vuong Hospital, Ho Chi Minh City, Vietnam.
Aims/introduction: Blood glucose meters are commonly used at the bedside, but most of the meters used in Hung Vuong Hospital (Ho Chi Minh City, Vietnam) are built for self-monitoring and might not be suitable for determining glucose levels in patients. In this study, we aimed to validate the performance of six frequently used meters in our hospital using the Clinical & Laboratory Standards Institute (CLSI) standard, and investigate the hematocrit impact on the accuracy of these meters.
Materials And Methods: A total of 135 pregnant women who underwent a 75-g oral glucose tolerance test consented to participate in the study at Hung Vuong Hospital.