Background: In neuroscience, Ca imaging is a prevalent technique used to infer neuronal electrical activity, often relying on optical signals recorded at low sampling rates (3 to 30 Hz) across multiple neurons simultaneously. This study investigated whether increasing the sampling rate preserves critical information that may be missed at slower acquisition speeds.
Methods: Primary neuronal cultures were prepared from the cortex of newborn pups. Neurons were loaded with Oregon Green BAPTA-1 AM (OGB1-AM) fluorescent indicator. Spontaneous neuronal activity was recorded at low (14 Hz) and high (500 Hz) sampling rates, and the same neurons (n = 269) were analyzed under both conditions. We compared optical signal amplitude, duration, and frequency.
Results: Although recurring Ca transients appeared visually similar at 14 Hz and 500 Hz, quantitative analysis revealed significantly faster rise times and shorter durations (half-widths) at the higher sampling rate. Small-amplitude Ca transients, undetectable at 14 Hz, became evident at 500 Hz, particularly in the neuropil (putative dendrites and axons), but not in nearby cell bodies. Large Ca transients exhibited greater amplitudes and faster temporal dynamics in dendrites compared with somas, potentially due to the higher surface-to-volume ratio of dendrites. In neurons bulk-loaded with OGB1-AM, cell nucleus-mediated signal distortions were observed in every neuron examined (n = 57). Specifically, two regions of interest (ROIs) on different segments of the same cell body displayed significantly different signal amplitudes and durations due to dye accumulation in the nucleus.
Conclusions: Our findings reveal that Ca signal undersampling leads to three types of information loss: (1) distortion of rise times and durations for large-amplitude transients, (2) failure to detect small-amplitude transients in cell bodies, and (3) omission of small-amplitude transients in the neuropil.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.31083/JIN26242 | DOI Listing |
J Integr Neurosci
January 2025
Neuroscience Department, University of Connecticut Health, School of Medicine, Institute for Systems Genomics, Farmington, CT 06030, USA.
Background: In neuroscience, Ca imaging is a prevalent technique used to infer neuronal electrical activity, often relying on optical signals recorded at low sampling rates (3 to 30 Hz) across multiple neurons simultaneously. This study investigated whether increasing the sampling rate preserves critical information that may be missed at slower acquisition speeds.
Methods: Primary neuronal cultures were prepared from the cortex of newborn pups.
J Phys Chem B
December 2024
School of Applied and Interdisciplinary Sciences, Indian Association for the Cultivation of Science, 2A & 2B Raja S. C. Mullick Road, Jadavpur, Kolkata 700032, India.
Langmuir
August 2024
Department of Chemistry, University of Bari "Aldo Moro", Via Orabona 4, Bari 70126, Italy.
The mechanical properties of multilamellar vesicles and their relevance to soft matter physics and material science are of significant interest. The bending rigidity, κ, and compression modulus, , of three-dimensional (3D) finite nonspontaneous multilamellar vesicles, formed by a nonionic surfactant, are linked to nanoscale bilayer thickness, δ, estimated via small-angle X-ray scattering, and macroscopic elastic modulus measured through small-amplitude oscillatory shear experiments. κ and significantly differ from the same system in the two-dimensional (2D) infinite nanostructured planar lamellar phase.
View Article and Find Full Text PDFSoft Matter
December 2023
Univ Lyon, CNRS, UMR 5223, Ingénierie des Matériaux Polymères, INSA Lyon, Université Claude Bernard Lyon 1, Université Jean Monnet, CEDEX, F-69621 Villeurbanne, France.
The present work has aimed at gaining a deeper understanding of the effects of shear flow on the behaviors of nano filler evolution inside linear and long chain branched polymer matrices. Accordingly, measurements consisting of transient start-up shear rheology coupled with small amplitude oscillatory sweep (SAOS) and dielectric tests were designed. Linear polypropylene (PPC) and polypropylene (PPH) with long chain branching (LCB) were chosen as the polymer matrices and carbon nanotubes (CNTs) as the nanofillers.
View Article and Find Full Text PDFJ Phys Chem Lett
September 2023
Department of Chemistry and Biochemistry, University of California, Santa Cruz, Santa Cruz, California 95064, United States.
The excited state dynamics of ligand-passivated PbBr molecular clusters (MCs) in solution have been investigated for the first time using femtosecond transient absorption spectroscopy. The results uncover a transient bleach (TB) feature peaked around 404 nm, matching the ground state electronic absorption band peaked at 404 nm. The TB recovery signal can be fitted with a triple exponential with fast (10 ps), medium (350 ps), and long (1.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!