AI Article Synopsis

Article Abstract

This study developed a scientific process parameter setup based on nozzle pressure and screw position, with the process parameter search sequence being injection speed, / switchover position, packing pressure, and packing time. Unlike previous studies, this study focuses on the scientific process parameter setup of experiments and simulations, as well as on the implementation of calibration. Experiments and simulations had the same trend of results in the scientific process parameter setup. Although the experiments and simulations had the same trend, the machine response caused parameter errors. After setting the time constant of the simulations, injection speed profiles from the experiments and simulations became closely aligned. The simulation results for the injection speed and / switchover position became closer to the experiment results than the results of the uncalibrated simulation. The error between the simulated and experimental injection speed was reduced from 20% to 6% after applying time constant calibration. The / switchover point error was also reduced from 11% to 5%, highlighting the effectiveness of the time constant to calibrate the simulation.

Download full-text PDF

Source
http://dx.doi.org/10.3390/polym17020198DOI Listing

Publication Analysis

Top Keywords

process parameter
20
scientific process
16
parameter setup
16
injection speed
16
experiments simulations
16
time constant
12
speed switchover
8
switchover position
8
setup experiments
8
simulations trend
8

Similar Publications

Surface water chemistry of the River Ganga at Varanasi was analyzed at 10 locations over 3 years (2019-2021) across pre-monsoon, monsoon, and post-monsoon seasons. The study aimed to assess water parameters using principal component analysis (PCA), calculate the water quality index (WQI), determine processes governing water chemistry, evaluate irrigation suitability, and estimate non-carcinogenic health risks. The physical parameters measured included pH (8.

View Article and Find Full Text PDF

We build and study an individual based model of the telomere length's evolution in a population across multiple generations. This model is a continuous time typed branching process, where the type of an individual includes its gamete mean telomere length and its age. We study its Malthusian's behaviour and provide numerical simulations to understand the influence of biologically relevant parameters.

View Article and Find Full Text PDF

Background: Evaluating professional values is crucial to developing effective strategies for integrating them into professional performance and clinical education. A standard questionnaire is an instrument that can be used to evaluate professional values. This study aimed to assess the validity and reliability of the Nurses Professional Values Scale-Revised (NPVS-R) among nursing students in the Persian language.

View Article and Find Full Text PDF

This study aims to explore the mechanism behind the influence of stress on gas adsorption by coal during deep mining and improve the accuracy of gas disaster prevention and control. To achieve this aim, thermodynamic analysis was conducted on the process of gas adsorption by loaded coal, and modified thermodynamic model proposed by previous scholars. It is found that stress plays an important role in gas adsorption by coal.

View Article and Find Full Text PDF

Mechanical ventilation is the process through which breathing support is provided to patients who face inconvenience during respiration. During the pandemic, many people were suffering from lung disorders, which elevated the demand for mechanical ventilators. The handling of mechanical ventilators is to be done under the assistance of trained professionals and demands the selection of ideal parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!