Terrestrial laser scanners (TLS) are portable dimensional measurement instruments used to obtain 3D point clouds of objects in a scene. While TLSs do not require the use of cooperative targets, they are sometimes placed in a scene to fuse or compare data from different instruments or data from the same instrument but from different positions. A contrast target is an example of such a target; it consists of alternating black/white squares that can be printed using a laser printer. Because contrast targets are planar as opposed to three-dimensional (like a sphere), the center of the target might suffer from errors that depend on the orientation of the target with respect to the TLS. In this paper, we discuss a low-cost method to characterize such errors and present results obtained from a short-range TLS and a long-range TLS. Our method involves comparing the center of a contrast target against the center of spheres and, therefore, does not require the use of a reference instrument or calibrated objects. For the short-range TLS, systematic errors of up to 0.5 mm were observed in the target center as a function of the angle for the two distances (5 m and 10 m) and resolutions (30 points-per-degree (ppd) and 90 ppd) considered for this TLS. For the long-range TLS, systematic errors of about 0.3 mm to 0.8 mm were observed in the target center as a function of the angle for the two distances (5 m and 10 m) at low resolution (28 ppd). Errors of under 0.3 mm were observed in the target center as a function of the angle for the two distances at high resolution (109 ppd).

Download full-text PDF

Source
http://dx.doi.org/10.3390/s25020505DOI Listing

Publication Analysis

Top Keywords

target center
16
errors observed
12
observed target
12
center function
12
function angle
12
angle distances
12
center contrast
8
contrast targets
8
terrestrial laser
8
laser scanners
8

Similar Publications

A Japanese woman with Li-Fraumeni syndrome in her 40s underwent comprehensive genetic profiling accompanied by germline data using the Oncoguide NCC Oncopanel, but no germline pathogenic variants in the tumor suppressor gene TP53 were detected. However, careful examination of additional data in the report suggested the presence of a large TP53 deletion. Custom targeting next-generation sequencing and nanopore sequencing revealed a 3.

View Article and Find Full Text PDF

Revolutionizing acute myeloid leukemia treatment: a systematic review of immune-based therapies.

Discov Oncol

January 2025

Division of Hematology/Oncology, The University of Texas Health Sciences Center at Houston, McGovern Medical School, 6431 Fannin Street, MSB 5.216, Houston, TX, 77030, USA.

The established protocol for the management of acute myeloid leukemia (AML) has traditionally involved the administration of induction chemotherapy, followed by consolidation chemotherapy, and subsequent allogeneic stem cell transplantation for eligible patients. However, the prognosis for individuals with relapsed and refractory AML remains unfavorable. In response to the necessity for more efficacious therapeutic modalities, targeted immunotherapy has emerged as a promising advancement in AML treatment.

View Article and Find Full Text PDF

In 2017, Kidney Disease: Improving Global Outcomes (KDIGO) published a Clinical Practice Guideline Update for the Diagnosis, Evaluation, Prevention, and Treatment of Chronic Kidney Disease-Mineral and Bone Disorder (CKD-MBD). Since then, new lines of evidence have been published related to evaluating disordered mineral metabolism and bone quality and turnover, identifying and inhibiting vascular calcification, targeting vitamin D levels, and regulating parathyroid hormone. For an in-depth consideration of the new insights, in October 2023, KDIGO held a Controversies Conference on CKD-MBD: Progress and Knowledge Gaps Toward Personalizing Care.

View Article and Find Full Text PDF

Study Objective: The osmol gap can help detect and manage those with toxic alcohol exposure, and it is altered by all alcohols including ethanol. The optimal correction for ethanol that would allow accurate detection of an alternative alcohol is unclear.

Methods: We conducted a prospective cohort study to assess baseline variations in osmol gap, and then to assess the validity of 2 commonly used coefficients (correction factors) for ethanol.

View Article and Find Full Text PDF

Introduction: Hemoperfusion (HP), a blood filtration method targeting the removal of toxins and inflammatory elements, was investigated in this study. The objective was to present the observations in four individuals with confirmed COVID-19 who underwent several rounds of HP utilizing the HA330 cartridge at a hospital in Indonesia.

Case Studies: We report four cases of COVID-19 patients who underwent HP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!